2 If AC is off, it will run in auto mode when the timer on function is active.
3 After setting the mode, AC will run in auto mode if the compressor keeps not running for
certain time.
10.4.5 Drying mode
8.4.5.1 The compressor is cycled running with 10 minutes on and then 5 minutes off. The indoor fan
will keep running at low speed.
8.4.5.2 In drying mode, if room temperature is lower than 10, the compressor will stop and not
resume until room temperature exceeds 13.
8.4.5.3 The evaporator anti-freezing protection is the same as that in cooling mode.
10.4.6 Forced operation function
Forced cooling mode:
The compressor and outdoor fan keep running and the indoor fan runs at low speed. After running for
30 minutes, AC will turn to auto mode with 24 setting temperature.
Forced auto mode:
The action of forced auto mode is the same as normal auto mode with 24 setting temperature.
When AC receives signals, such as switch on, switch off, timer on, timer off, mode setting, fan speed
setting, sleeping mode setting, follow me setting, it will quit the forced operation.
10.4.7 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before the
power failure. The unit will resume the previous operation setting (not including swing function)
automatically after 3 minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes
and turn to auto mode as 24 setting temp.
If AC is off before power off and AC is required to start up now, the compressor will have 1 minute
delay when power on. Other conditions, the compressor will have 3 minutes delay when restarts.
10.4.8 Refrigerant Leakage Detection
With this new technology, the display area will show “EC” when the outdoor unit detects refrigerant
leakage.
When compressor is active, the value of the Coil temperature of evaporator T2 has no change or very
little change.
10.4.9 8 Heating(optional)
When the compressor is running, the indoor fan motor will run without anti-cold air function.
When the compressor is off, the indoor fan motor is off .
10.4.10 Self clean (optional)
For heat pump models which are provided with this function, after running in cooling or drying mode, if
the user press “Self Clean” button on remote controller, firstly, indoor unit runs in fan only mode for a
while, then low heat operation and finally runs in fan only again. This function can keep the inside of
indoor unit dry and prevent breeding of mold.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea Blanc ON-OFF Series and is the answer not in the manual?

Midea Blanc ON-OFF Series Specifications

General IconGeneral
BrandMidea
ModelBlanc ON-OFF Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals