EasyManuals Logo

Midea DLCERAA18AAK User Manual

Midea DLCERAA18AAK
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
32 32808001101
Specifications subject to change without notice.
DIAGNOSIS AND SOLUTION (CONT)
Open circuit or short circuit of temperature sensor diagnosis and solution (E4/E5/F1/F2/F3)
Error Code E4/E5/F1/F2/F3
Malfunction decision conditions If the sampling voltage is lower than 0.06V or higher than 4.94V, the LED displays the failure.
Supposed causes
S Wiring mistake
S Sensor faulty
S PCB faulty
Troubleshooting
Check the connection
between the temperature
sensor and PCB.
Correct the connectionNo
Yes
Replace indoor or outdoor
main PCB
Measure the resistance
value of the sensor
Replace the sensorNo
Yes
Fig. 35 - Check the connection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea DLCERAA18AAK and is the answer not in the manual?

Midea DLCERAA18AAK Specifications

General IconGeneral
BrandMidea
ModelDLCERAA18AAK
CategoryAir Conditioner
LanguageEnglish

Related product manuals