EasyManua.ls Logo

Midea EasyCool Window MAW Series - User Manual

Midea EasyCool Window MAW Series
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EasyCool Window
version A - 11 - 2018
MAW12S1YWT
MAW10S1YWT
MAW08S1YWT
MAW06R1YWT
MAW05R1YWT
MAW05M1YWT
midea.com
USER MANUAL
en
MAW
Warning notices: Before
using this product, please
read this manual carefully
and keep it for future
reference.
The design and
specifications are subject to
change without prior notice
for product improvement.
Consult with your dealer or
the manufacturer for details.
Frequency: 60Hz
Capacity: 5000 ~ 12000BTU/h
ow
US
ER MAN
U
A
L
0
00BTU
/h
version A - 11 - 2018 (PREVIEW03)

Questions and Answers

Summary

Safety Precautions

Operation of Current Device

Explains the function of the power supply cord's current detection device.

Operating Instructions

Normal Sounds

Describes common operational sounds like rushing air, chatter, gurgling, and trickling.

Air Conditioner Operation

Provides steps and conditions for operating the air conditioner.

Unit Controls

Details thermostat, cool mode, and fan mode settings for unit operation.

Key Pad Features

Explains buttons and functions like ON/OFF, MODE, FAN, and TEMP for specific models.

Control Functions and Display

Details fan speed, ECO, Sleep, Timer, Check Filter, LED display, and error codes.

Additional Information

Explains features like time delayed start, temperature display, and fresh air vent control.

Installation Instructions

Installation Preparation

Provides essential warnings and recommendations before starting installation.

Window and Unit Preparation

Details preparing the window opening and assembling the top rail on the unit.

Install Accordion Panels

Guide on how to install the accordion side panels into the unit frame.

Install Support Bracket

Instructions for installing the support bracket for securing the unit.

Secure Unit and Removal

Details securing lower sash, window foam, and procedures for removing the AC.

Care and Cleaning

Air Filter Cleaning

Step-by-step guide on how to check, wash, and dry the air filter.

Cabinet Cleaning

Instructions for dusting and washing the air conditioner cabinet and front panel.

Winter Storage

Guidance on storing the air conditioner during winter or off-season.

Troubleshooting Tips

Remote Control Instructions

Handling the Remote Controller

Provides guidelines on proper handling and location of the remote controller.

Replacing the Remote Battery

Step-by-step instructions for replacing the battery in the remote control.

Remote Control Specifications

Lists technical specifications for the remote control model RG15A(B)/E.

Remote Function Buttons

Details the functions of each button on the remote control for operation.

Using Remote Control Buttons

Explains how to use buttons for Auto operation and Cooling/Fan modes.

Remote Operation Modes

Details Dehumidifying and Timer operations using the remote control.

Combined Timer Functions

Explains setting both ON and OFF timers simultaneously for convenience.

Energy Saver Operation

Describes the Energy Saver mode and its fan operation after compressor shut-off.

Overview

This document is a user manual for Midea EasyCool Window Air Conditioners, specifically models MAW12S1YWT, MAW10S1YWT, MAW08S1YWT, MAW06R1YWT, MAW05R1YWT, and MAW05M1YWT. It provides comprehensive instructions for installation, operation, maintenance, and troubleshooting.

Function Description:

The Midea EasyCool Window Air Conditioner is designed to provide cooling for indoor spaces. It operates on a 60Hz frequency and offers a cooling capacity ranging from 5000 to 12000 BTU/h, depending on the model. The unit can be controlled via a control panel on the unit itself or with a remote controller. Key operating modes include Cool, Fan, Dry (dehumidifier), and Auto. It also features an Energy Saver function, Sleep mode, and a Timer function for scheduled operation. Some models include a Fresh Air Vent control for recirculating indoor air, drawing in fresh air, or exchanging air. Air directional louvers allow users to adjust the airflow direction.

Important Technical Specifications:

  • Models Covered: MAW12S1YWT, MAW10S1YWT, MAW08S1YWT, MAW06R1YWT, MAW05R1YWT, MAW05M1YWT.
  • Frequency: 60Hz.
  • Cooling Capacity: 5000 ~ 12000 BTU/h.
  • Refrigerant: R32 (flammable refrigerant, requiring specific handling and disposal procedures).
  • Operating Temperature Range (Cooling):
    • Outdoor: 18-43°C (64-109°F)
    • Indoor: 17-32°C (62-90°F)
  • Desired Temperature Setting Range: 17-30°C (62-86°F).
  • Power Supply Cord: Equipped with a current detection device to reduce fire risk.
  • Installation: Designed for standard double-hung windows with opening widths of 23 to 36 inches (584mm to 914mm).
  • Remote Control (RG15A(B)/E):
    • Rated Voltage: 3.0V (Lithium battery CR2025)
    • Lowest Voltage of CPU Emitting Signal: 2.4 V
    • Signal Receiving Range: 16.4 ft (5 m)
    • Environment Temperature: -5°C ~ 60°C (23°F ~ 140°F)
  • Safety Features: Automatic 3-minute time delayed start for the cool circuit to prevent compressor overheating and circuit breaker tripping. Grounding is essential for minimizing shock and fire hazards.

Usage Features:

  • Control Panel: Features buttons for ON/OFF, Timer, Sleep, Mode (Auto, Cool, Dry, Fan), Up/Down (temperature/timer adjustment), Fan Speed (Auto, Low, Med, High), ECO (Energy Saver), and Check Filter. Some models (Wi-Fi enabled) also have a Connect Indicator Light.
  • LED Display: Shows set temperature (°C or °F), Auto-timer settings, and actual room temperature in Fan Only mode. Displays error codes (AS for room temperature sensor, ES for evaporator temperature sensor, HS for electric heating sensor).
  • Operating Modes:
    • Cool Mode: Provides maximum cooling with adjustable fan speeds.
    • Fan Mode: Circulates room air without cooling; fan speed is adjustable.
    • Dry Mode: Functions as a dehumidifier; fan speed is automatically controlled to Low.
    • Auto Mode: Automatically selects cooling or fan-only operation based on selected temperature and current room temperature; fan speed is automatically controlled.
  • Energy Saver (ECO) Function: The fan runs for 3 minutes after the compressor shuts off, then cycles on for 2 minutes at 10-minute intervals until the room temperature rises above the set temperature, at which point cooling resumes. Available in Cool, Dry, and Auto modes.
  • Sleep Mode: Gradually increases the set temperature by 2°F/1°C after 30 minutes, and again after another 30 minutes, maintaining this new temperature for 7 hours before returning to the original setting. Available in Cool and Auto modes.
  • Timer Function: Allows scheduling of Auto Start and Auto Stop programs, adjustable in 0.5-hour increments up to 10 hours, then 1-hour increments up to 24 hours.
  • Fresh Air Vent Control (MAW10 to MAW12): Allows selection between recirculating indoor air (Vent Closed), drawing in fresh air (Vent Open), or exchanging air (Vent and Exhaust Open).
  • Air Directional Louvers: Horizontal louvers pivot for up/down airflow, and levers move side-to-side for left/right airflow.
  • Remote Control: Provides full functionality of the unit from a distance of up to 16.4 ft (5 meters). Requires a CR2025 lithium battery.

Maintenance Features:

  • Air Filter Cleaning: Recommended at least once a month. The filter can be washed with liquid dishwashing detergent and warm water, rinsed, and dried, or vacuumed. The "Check Filter" LED illuminates after 250 hours of operation as a reminder.
  • Cabinet Cleaning: The cabinet and front can be dusted with an oil-free cloth or washed with a damp cloth and mild liquid dishwashing detergent. Harsh cleansers, wax, or polish should be avoided.
  • Winter Storage: If storing the unit for winter, it should be removed from the window, covered with plastic, or returned to its original carton.
  • Troubleshooting Tips: The manual includes a list of common problems and their solutions, such as the unit not starting, insufficient cooling, ice formation on coils, rapid cycling, noise, and water dripping.
  • Safety Precautions: Emphasizes unplugging the unit before cleaning, proper grounding, avoiding damage to the power cord, and proper ventilation when using near gas-burning devices. Specific warnings are provided for units using R32 flammable refrigerant, including not piercing or burning refrigerant tubing and ensuring proper ventilation.
  • Professional Service: Recommends contacting an authorized service technician for repairs, maintenance, or power cord replacement, and a qualified electrician for electrical installation or if aluminum house wiring presents problems.

Midea EasyCool Window MAW Series Specifications

General IconGeneral
BrandMidea
ModelEasyCool Window MAW Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals