EasyManua.ls Logo

Midea EasyCool Window MAW06R1YWT - User Manual

Midea EasyCool Window MAW06R1YWT
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EasyCool Window
version A - 11 - 2018
MAW12S1YWT
MAW10S1YWT
MAW08S1YWT
MAW06R1YWT
MAW05R1YWT
MAW05M1YWT
midea.com
USER MANUAL
en
MAW
Warning notices: Before
using this product, please
read this manual carefully
and keep it for future
reference.
The design and
specifications are subject to
change without prior notice
for product improvement.
Consult with your dealer or
the manufacturer for details.
Frequency: 60Hz
Capacity: 5000 ~ 12000BTU/h
ow
US
ER MAN
U
A
L
0
00BTU
/h
version A - 11 - 2018 (PREVIEW03)

Questions and Answers

Summary

Safety Precautions

General Electrical and Operational Safety

Warnings about power, grounding, wet hands, flammable materials, and unit operation.

Refrigerant Fire Hazard Warning

Warning about flammable refrigerant and potential fire risk if leaked.

Electrical System and Installation Safety

Warnings about power cords, circuit breakers, dedicated circuits, and proper installation.

R32 Refrigerant Handling and Safety

Specific warnings for R32 refrigerant, including ignition sources and servicing.

Power Cord Safety and Grounding

Notes on power cord features, safety, and proper grounding of the unit.

Electrical Installation and Receptacle Safety

Requirements for proper grounding, circuit breakers, and accessible receptacles.

Operating Instructions

Key Pad Functions and Modes

Explains the function of each button and different operating modes like Auto, Fan, Dry.

Installation Instructions

Pre-Installation Safety and Requirements

Important safety notes, codes, and skill level required before installation.

Positioning and Securing the Unit in Window

How to carefully place the unit in the window and ensure proper tilt for drainage.

Care and Cleaning

Air Filter Cleaning Procedure

How to check, remove, wash, and dry the air filter for optimal performance.

Troubleshooting Tips

Troubleshooting Unit Not Starting

Solutions for when the air conditioner fails to power on or operate.

Troubleshooting Cooling Performance Issues

Explains why cooling might be insufficient and how to address it.

Remote Control Instructions

Remote Control Function Button Guide

Explains the purpose and operation of each button on the remote control.

Summary

Safety Precautions

General Electrical and Operational Safety

Warnings about power, grounding, wet hands, flammable materials, and unit operation.

Refrigerant Fire Hazard Warning

Warning about flammable refrigerant and potential fire risk if leaked.

Electrical System and Installation Safety

Warnings about power cords, circuit breakers, dedicated circuits, and proper installation.

R32 Refrigerant Handling and Safety

Specific warnings for R32 refrigerant, including ignition sources and servicing.

Power Cord Safety and Grounding

Notes on power cord features, safety, and proper grounding of the unit.

Electrical Installation and Receptacle Safety

Requirements for proper grounding, circuit breakers, and accessible receptacles.

Operating Instructions

Key Pad Functions and Modes

Explains the function of each button and different operating modes like Auto, Fan, Dry.

Installation Instructions

Pre-Installation Safety and Requirements

Important safety notes, codes, and skill level required before installation.

Positioning and Securing the Unit in Window

How to carefully place the unit in the window and ensure proper tilt for drainage.

Care and Cleaning

Air Filter Cleaning Procedure

How to check, remove, wash, and dry the air filter for optimal performance.

Troubleshooting Tips

Troubleshooting Unit Not Starting

Solutions for when the air conditioner fails to power on or operate.

Troubleshooting Cooling Performance Issues

Explains why cooling might be insufficient and how to address it.

Remote Control Instructions

Remote Control Function Button Guide

Explains the purpose and operation of each button on the remote control.

Overview

This document is a user manual for Midea EasyCool Window Air Conditioners, specifically models MAW12S1YWT, MAW10S1YWT, MAW08S1YWT, MAW06R1YWT, MAW05R1YWT, and MAW05M1YWT. It provides comprehensive instructions for installation, operation, maintenance, and troubleshooting.

Function Description:

The Midea EasyCool Window Air Conditioner is designed to provide cooling for indoor spaces. It operates on a 60Hz frequency and offers a cooling capacity ranging from 5000 to 12000 BTU/h, depending on the model. The unit can be controlled via a control panel on the unit itself or with a remote controller. Key operating modes include Cool, Fan, Dry (dehumidifier), and Auto. It also features an Energy Saver function, Sleep mode, and a Timer function for scheduled operation. Some models include a Fresh Air Vent control for recirculating indoor air, drawing in fresh air, or exchanging air. Air directional louvers allow users to adjust the airflow direction.

Important Technical Specifications:

  • Models Covered: MAW12S1YWT, MAW10S1YWT, MAW08S1YWT, MAW06R1YWT, MAW05R1YWT, MAW05M1YWT.
  • Frequency: 60Hz.
  • Cooling Capacity: 5000 ~ 12000 BTU/h.
  • Refrigerant: R32 (flammable refrigerant, requiring specific handling and disposal procedures).
  • Operating Temperature Range (Cooling):
    • Outdoor: 18-43°C (64-109°F)
    • Indoor: 17-32°C (62-90°F)
  • Desired Temperature Setting Range: 17-30°C (62-86°F).
  • Power Supply Cord: Equipped with a current detection device to reduce fire risk.
  • Installation: Designed for standard double-hung windows with opening widths of 23 to 36 inches (584mm to 914mm).
  • Remote Control (RG15A(B)/E):
    • Rated Voltage: 3.0V (Lithium battery CR2025)
    • Lowest Voltage of CPU Emitting Signal: 2.4 V
    • Signal Receiving Range: 16.4 ft (5 m)
    • Environment Temperature: -5°C ~ 60°C (23°F ~ 140°F)
  • Safety Features: Automatic 3-minute time delayed start for the cool circuit to prevent compressor overheating and circuit breaker tripping. Grounding is essential for minimizing shock and fire hazards.

Usage Features:

  • Control Panel: Features buttons for ON/OFF, Timer, Sleep, Mode (Auto, Cool, Dry, Fan), Up/Down (temperature/timer adjustment), Fan Speed (Auto, Low, Med, High), ECO (Energy Saver), and Check Filter. Some models (Wi-Fi enabled) also have a Connect Indicator Light.
  • LED Display: Shows set temperature (°C or °F), Auto-timer settings, and actual room temperature in Fan Only mode. Displays error codes (AS for room temperature sensor, ES for evaporator temperature sensor, HS for electric heating sensor).
  • Operating Modes:
    • Cool Mode: Provides maximum cooling with adjustable fan speeds.
    • Fan Mode: Circulates room air without cooling; fan speed is adjustable.
    • Dry Mode: Functions as a dehumidifier; fan speed is automatically controlled to Low.
    • Auto Mode: Automatically selects cooling or fan-only operation based on selected temperature and current room temperature; fan speed is automatically controlled.
  • Energy Saver (ECO) Function: The fan runs for 3 minutes after the compressor shuts off, then cycles on for 2 minutes at 10-minute intervals until the room temperature rises above the set temperature, at which point cooling resumes. Available in Cool, Dry, and Auto modes.
  • Sleep Mode: Gradually increases the set temperature by 2°F/1°C after 30 minutes, and again after another 30 minutes, maintaining this new temperature for 7 hours before returning to the original setting. Available in Cool and Auto modes.
  • Timer Function: Allows scheduling of Auto Start and Auto Stop programs, adjustable in 0.5-hour increments up to 10 hours, then 1-hour increments up to 24 hours.
  • Fresh Air Vent Control (MAW10 to MAW12): Allows selection between recirculating indoor air (Vent Closed), drawing in fresh air (Vent Open), or exchanging air (Vent and Exhaust Open).
  • Air Directional Louvers: Horizontal louvers pivot for up/down airflow, and levers move side-to-side for left/right airflow.
  • Remote Control: Provides full functionality of the unit from a distance of up to 16.4 ft (5 meters). Requires a CR2025 lithium battery.

Maintenance Features:

  • Air Filter Cleaning: Recommended at least once a month. The filter can be washed with liquid dishwashing detergent and warm water, rinsed, and dried, or vacuumed. The "Check Filter" LED illuminates after 250 hours of operation as a reminder.
  • Cabinet Cleaning: The cabinet and front can be dusted with an oil-free cloth or washed with a damp cloth and mild liquid dishwashing detergent. Harsh cleansers, wax, or polish should be avoided.
  • Winter Storage: If storing the unit for winter, it should be removed from the window, covered with plastic, or returned to its original carton.
  • Troubleshooting Tips: The manual includes a list of common problems and their solutions, such as the unit not starting, insufficient cooling, ice formation on coils, rapid cycling, noise, and water dripping.
  • Safety Precautions: Emphasizes unplugging the unit before cleaning, proper grounding, avoiding damage to the power cord, and proper ventilation when using near gas-burning devices. Specific warnings are provided for units using R32 flammable refrigerant, including not piercing or burning refrigerant tubing and ensuring proper ventilation.
  • Professional Service: Recommends contacting an authorized service technician for repairs, maintenance, or power cord replacement, and a qualified electrician for electrical installation or if aluminum house wiring presents problems.

Midea EasyCool Window MAW06R1YWT Specifications

General IconGeneral
TypeWindow Air Conditioner
Cooling Capacity6, 000 BTU
Energy Efficiency Ratio (EER)11.0
Voltage115V
Noise Level52 dB
EER11.0
Coverage AreaUp to 250 sq. ft.
Fan Speeds3
Power Supply115V/60Hz
RefrigerantR32
Installation TypeWindow
FeaturesRemote Control
Control TypeElectronic
Operating Current5.3A
Noise Level (Low/High)52 dB