M‐ThermalSplit
20190969
4.18 P5Troubleshooting
Digitaldisplayoutput

Description
High temperature difference between water side heat exchanger water inlet and water outlet temperatures
protection.
M‐ThermalSplitstopsrunning.
ErrorcodeisdisplayedonhydronicboxmainPCBanduserinterface.
Possiblecauses
Temperaturesensornotconnectedproperlyorhasmalfunctioned.
Waterpipingcontainsair.
Insufficientwaterflow.
HydronicboxmainPCBdamaged.
