Loading...
Service manual DM16-01.01.11-01en
52 Multi DC inverter R410A. Outdoor unit
11.3.2.10 IPM module protection (ODU P6)
IPMmoduleprotection
Checkwhetherthevoltagerange
ofPNonIPMmoduleisnormal?
DC277356Vfor1828KBtu/h;
DC277410Vfor3642KBtu/h
Yes
Yes
No
Yes
Checkwhethertheinput
powersupplyiscorrect?
208230V,1N,60Hz
No No
Regulateittocorrect,then
checkwhetherthesystem
canworknormally?
Checkwhetherthe
powersupplylineis
connectedcorrectlyand
tightly
Yes
Connectitcorrectly
andtightly,checkok
ornot?
No
Checkwhethertheconnecting
linebetweenmainboardand
theIPMmoduleisconnected
tightly
Yes
Connectittightly,
checkokornot?
No
No
No
Connectitwell,check
okornot?
Checkwhethertheconnecting
lineofthecompressoris
connectedcorrectlyortightly
ReplacetheIPMmodule,
checkwhetherthesystemcan
worknormally?
No
No
Replacethemainboard;check
whetherthesystemcanwork
normally?
No
Replacethecompressor,check
whetherthesystemcanwork
normally?
Checkwhetherthelines
inEpartboxare
connectedtightly
Yes
Connectittightly,
checkokornot?
No
No
Yes
No
Replacethebridgerectifiers
Checkwhetherthebridgerectifiersare
normal?Usethemultimetertomeasure
theresistancebetweeneachtwo
terminals,checkwhetherthereisthe
conditionthatvalueofresistanceis0
Check whether the connecting line of
every reactor is normal? If the line is
broken,theresistanceofthetwoportsis
models except for M4OA36HFN1
Q,M4OD28HFN1Q, M5OC36HFN1
Q);Check whether the PFC module
broken (for M4OA36HFN1Q,M4OD
28HFN1Q, M5OC36HFN1Q,M50D
42HFN1Q)
Replacetheconnectinglineor
reactororreplacethePFC
module(forM4OC36HRFN1
M,M50D42HFN1Q)
Yes
No
No
Yes
Troubleissolved
Checkiftheoutdoorfan
runsproperlyortheoutdoor
unitventilationisgood.
No
Checkwhether theresistanceof
the fan motor is normal. If not,
replace the fan motor.
For other
models, r
efer to the solution of
fan speed has been out of
control malfunction . Find out
thecauseandhaveitsolved.
Yes
Yes