9.  Troubleshooting 
9.1   Indoor unit error code explanation: 
Vertu series & 9A series: 
Display  LED STATUS 
E0  EEPROM parameter error 
E1  Communication malfunction between indoor and outdoor units 
E2  Zero-crossing signal error 
E3  Indoor fan speed out of control 
E5 
Open or short circuit of outdoor temperature sensor 
E6 
Open or short circuit of room or evaporator coil temperature sensor 
P0  Inverter module protection 
P1  Over voltage or too low voltage protection 
P2  Temperature protection of compressor top. 
P3  Outdoor temp. too low protection 
P4  Inverter compressor drive error 
9.2 Outdoor unit error code explanation: 
Display  LED STATUS 
E0  EEPROM parameter error 
E1  No 1 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective 
E2  No 2 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective 
E3  No 3 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective 
E6  No 4 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective 
E4  Open or short circuit of outdoor temperature sensor 
E5  Compressor volt protection 
E7  Communication error between outdoor IC and DSP 
P0  Temperature protection of compressor top.  
P1  High pressure protection (just for 36K 1x4 units.) 
P2  Low pressure protection (just for 36K 1x4 units.) 
P3  Compressor current protection 
P4  Inverter module protection 
P5  Outdoor temp. too low protection 
P6  Condenser high-temperature protection 
P7  Compressor driving protection 
PF  PFC protection (just for 36K 1x4 units.)