Drainage guide
During dehumidifying modes, remove the upper drain plug from the back 
of the unit, install the drain connector(5/8" universal female mender) with
3/4" hose(locally purchased). For the models without  drain connector, 
just attach the drain hose to the hole. Place the open end of the hose 
directly over the drain area in your basement floor.
During heating pump mode,  carefully move the unit to a drain location,and let 
the water drain away. 
When the water level of the bottom tray 
reaches a predetermined  level, the unit 
beeps 8 times, the digital display area 
shows "P1" . At this time the air 
conditioning/dehumidification process 
will  immediately stop. However, the fan 
motor will continue to operate 
(this is normal). Carefully move the unit 
to a drain location, remove the bottom 
drain plug and let the water drain away.
Reinstall the bottom drain plug  and 
restart the machine until the "P1" symbol 
disappears. If the error repeats, call for 
service.
During heating pump mode, 
remove the lower drain plug 
from the back of the unit, 
install the drain connector 
(5/8" universal female mender)
with 3/4" hose(locally purchased).
 For the models without drain 
connector, just attach the drain 
hose to the hole.
Place the open end of the Hose
adaptor directly over the drain 
area in your basement floor.
Continuous 
drain hose
Remove the 
upper drain
plug
23
Continuous 
drain hose
drain hose
adaptor
√√
delivery lift <1.8m
X
drain hose
adaptor
Press the power
cord buckle into
the rear cover.
 
Continuous 
drain hose
Remove the 
lower drain
plug
NOTE
NOTE
Make sure the hose is secure so there are no leaks. Direct the hose toward
the drain, making sure that there are no kinks that will stop the warter
flowing. Place the end of the hose into the drain and make sure the end of 
the hose is down to let the water flow smoothly. Do never let the end of the 
hose up. When the continuous drain hose is not used, ensure that the 
corresponding drain plug and knob are installed firmly to prevent leakage.
Be sure to reinstall the bottom drain 
plug firmly to prevent leakage before 
usingthe unit.
NOTE