MCAC-ATSM-201704 Aqua Tempo Super II Series DC Inverter Air-cooled chiller unit (50Hz)
20
10.2 Heating
MC-SU30-RN1L
Ambient
temp.
Chilledwateroutlettemperature(℃)
30.00 35.00 40.00 45.00 50.00 55.00
Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power
-15.00 17.38 8.03 16.06 8.22 16.80 8.60 15.35 9.65 / / / /
-7.00 25.44 8.85 24.41 9.46 24.32 9.90 23.33 11.11 20.23 11.21 / /
2.00 25.67 8.04 25.05 8.51 24.23 8.90 23.94 9.99 20.76 10.08 / /
7.00 31.84 8.17 33.80 8.95 32.95 9.36 32.31 10.51 28.01 10.60 22.19 9.20
15.00 34.27 5.35 32.23 5.77 27.58 5.86 24.21 6.64 23.54 7.93 21.97 8.70
20.00 33.69 4.51 30.77 4.67 25.45 4.63 21.57 5.10 20.87 6.08 19.43 6.73
25.00 33.75 4.18 31.22 4.34 26.34 4.31 22.82 4.78 22.62 5.77 21.61 6.38
Note:
This table is measured in rated water flow.
MC-SU60-RN1L
Ambient
temp.
Chilledwateroutlettemperature(℃)
30.00 35.00 40.00 45.00 50.00 55.00
Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power
-15.00 28.07 12.66 25.94 12.96 27.23 13.35 24.87 15.51 / / / /
-7.00 51.23 16.95 49.16 18.12 49.13 18.66 47.13 21.67 40.86 21.87 / /
2.00 45.39 14.12 44.28 14.96 42.96 15.40 42.45 17.89 36.81 18.05 / /
7.00 61.57 16.10 65.37 17.64 63.91 18.16 62.67 21.09 54.34 21.28 43.04 18.47
15.00 66.27 10.54 62.32 11.37 53.50 11.38 46.97 13.33 45.67 15.93 42.61 17.46
20.00 65.14 8.90 59.50 9.21 49.37 8.97 41.84 10.24 40.49 12.21 37.69 13.52
25.00 65.26 8.23 60.37 8.54 51.09 8.36 44.26 9.60 43.87 11.59 41.91 12.81
Note:
This table is measured in rated water flow.