Precautions
240
Indication of fault
Cause of fault
Phenomenon
of fault
Alarm of the
buzzing sound
Solution of alarm
Alarm for
temperature
exceed
The machine
temperature is
too high.
"
indicator flash
Airing"
The buzzer goes
on buzzing sound
for 10 seconds.
If the alarm does
not be solved ,
every 16 minutes
re-buzzs for
10 seconds.
Power off wait the
heating tempera-
ture fall then start
Alarm for
the door open
Open the door
after program
start
"Half" indication
flash
Close the door
solve alarm,reat-
art the program.
Alarm for
malfunction of
temperature
sensor
"Half+Airing"
indication flash
Temperature
sensor open
Power off check
themachine start
it when in normal
Temperature
sensor short
"Full"
indication flash
Other functions description
Other functions description and Technical Specifications
Technical Specifications