Cooling Capacity | 7.1 kW |
---|---|
Heating Capacity | 8.0 kW |
Refrigerant | R410A |
Power Supply | 220-240V, 50Hz |
Indoor Unit Type | Wall-mounted |
Details on panel design, compact size, airflow, air quality, auto swing, water pump, condensation, and auto restart.
Technical specifications including model, power, cooling/heating capacity, fan motor, coil, air flow, and dimensions.
Detailed dimensional drawings and measurements for various one-way cassette models.
Guidelines on recommended installation locations and clearance requirements.
Schematic diagram illustrating the refrigerant piping connections for the unit.
Electrical wiring diagrams showing connections for indoor unit components and external controls.
Cooling and heating capacity data based on varying indoor and outdoor temperature conditions.
Electrical parameters including voltage, current, power supply, and fan motor ratings.
Sound pressure level data (dB(A)) for different fan speeds and frequency bands.
List of standard accessories included with the one-way cassette indoor unit.
Highlights low noise, efficient cooling, stylish design, thin body, convenient installation, auto restart, and easy maintenance.
Technical specifications for two-way cassette models including capacity, power, fan motor, coil, and dimensions.
Detailed dimensional drawings for various two-way cassette models.
Installation site requirements and clearance guidelines for two-way cassette units.
Schematic of refrigerant piping for the two-way cassette unit.
Electrical wiring schematic for the two-way cassette indoor unit.
Cooling and heating capacity performance data based on varying operating conditions.
Electrical specifications including voltage, current, and power ratings for two-way cassette models.
Sound pressure level measurements (dB(A)) for different fan speeds across various models.
List of standard accessories provided with the two-way cassette indoor unit.
Highlights quiet operation, uniform airflow, ultra-thin body, low noise, reliability, and ease of installation.
Technical specifications for compact four-way cassette models, including capacity and dimensions.
Dimensional data and drawings for compact four-way cassette indoor units.
Installation site and clearance requirements for compact four-way cassette units.
Refrigerant piping diagram with EXV location for compact four-way cassettes.
Electrical wiring schematic for compact four-way cassette indoor units.
Cooling and heating capacity performance data based on varying indoor and outdoor conditions.
Electrical specifications including voltage, current, and power ratings for compact four-way units.
Sound pressure level (dB(A)) measurements for compact four-way cassette models.
List of attached and locally purchased accessories for compact four-way cassette units.
Highlights low noise, efficient cooling, excellent performance, 3D fan, digital display, fresh air, drainage pump, and thin body.
Technical specifications for four-way cassette models: capacity, power, fan motor, coil, and dimensions.
Dimensional drawings and specifications for various four-way cassette models.
Installation site requirements and clearance for four-way cassette units.
Schematic of refrigerant piping connections for four-way cassette units.
Electrical wiring diagrams for four-way cassette indoor units.
Cooling and heating capacity performance data based on varying indoor and outdoor temperatures.
Electrical parameters including voltage, current, power supply, and fan motor ratings.
Sound pressure level (dB(A)) measurements for four-way cassette models across fan speeds.
List of attached and local purchased accessories for four-way cassette indoor units.
Highlights external appearance, uniform airflow, ultra-thin body, low sound, reliability, and easier installation/maintenance.
Technical specifications for silent four-way cassette models: capacity, power, fan motor, coil, and dimensions.
Dimensional drawings for silent four-way cassette indoor units, specifying dimensions A and B.
Installation site requirements and clearance guidelines for silent four-way cassette units.
Schematic of refrigerant piping connections and port diameters.
Electrical wiring diagram for silent four-way cassette indoor units.
Cooling capacity tables based on varying indoor and outdoor temperatures.
Electrical specifications including voltage, current, and power supply ratings.
Sound pressure level measurements (dB(A)) and octave band levels for silent four-way cassette models.
List of attached and local purchased accessories for silent four-way cassette units.