MCAC-UTSM-2012-12 R410A 50Hz Tropical Split AC
11
Model
MHB-76CRN1
MHB-76HRN1
MHB-96CRN1
MHB-96HRN1
Power supply
-
220~240V-1Ph-50Hz
220~240V-1Ph-50Hz
Temp. setting range
℃
17~32
20~27
17~32
20~27
Rated input power
W
11700
11700
14400
14400
Rated current
A
19.3
19.3
23.7
23.7
Cooling
Capacity
Btu/h
75100
75100
95500
95500
W
22000
22000
28000
28000
Input power
W
7500
7500
9600
9600
EER
W/W
2.93
2.93
2.92
2.92
Heating
Capacity
Btu/h
/
85300
/
105800
w
/
25000
/
31000
Input power
W
/
8300
/
10300
COP
W/W
/
3.01
/
3.01
Indoor air flow (Hi/Med/Lo)
m
3
/h
4250/3620/3025
4250/3620/3025
5100/4580/3980
5100/4580/3980
Indoor standard ESP(Hi)
Pa
196
196
196
196
Indoor noise level (Hi)
dB(A)
53
53
54
54
Refrigerant
Type
-
R410A
R410A
R410A
R410A
Control
-
Capillary
Capillary
Fan
Type
-
Centrifugal fan
Centrifugal fan
Centrifugal fan
Centrifugal fan
Dimension
mm
Φ307
Φ307
Φ307
Φ307
Drive type
-
Direct
Direct
Direct
Direct
Motor input* No.
W
663*2
663*2
788*2
788*2
Motor speed
rpm
1022/871/758
1022/871/758
1135/983/845
1135/983/845
Coil
Type
-
Copper tube and aluminum fin
Copper tube and aluminum fin
Tube size
mm
Φ9.52
Φ9.52
Φ9.52
Φ9.52
No. of rows
-
3
3
4
4
Fin per inch
FPI
17
17
17
17
Length*Height
mm
1200*406.4
1200*406.4
1200*406
1200*406
Controller
-
Remote controller
Remote controller
Drain pipe size
mm
41
41
41
41
Dimension (W*H*D)
mm
1350*450*760
1350*450*760
1350*450*760
1350*450*760
Packing (W*H*D)
mm
1549*476*917
1549*476*917
1549*476*917
1549*476*917
Net/Gross weight
kg
105/120
105/120
105/120
105/120
Shipping Qty per (20'/40'/40'HD)
pcs
30/64/64
30/64/64
30/64/64
30/64/64
Notes:
1. ESP: external static pressure
2. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB, 24°C WB; Equivalent refrigerant piping: 7.5m (horizontal).
3. Nominal heating capacities are based on the following conditions:
Indoor temp: 20°CDB, 15°C WB; Outdoor temp: 7°CDB, 6°CWB; Equivalent refrigerant piping: 7.5m (horizontal).