56
unit
MHC-
V7W/D2
N1
MHC-
V9W/D2
N1
MHC-
V10W/D2
N1
MHC-
V12W/D2
N1
MHC-
V14W/D
2
N1
MHC-
V12W/D2
RN1
MHC-
V14W/D2
RN1
MHC-
V16W/D2
RN1
[dB(A)] / / / / / / / / /
[dB(A)] 61 65 66 67 71
71
68
71
71
Capacity of the
back-up heate
r
integrated in
the unit
Psup back-up heater [kW] 0
0
3 3 3
3
5
5
5
Y/N No
No
No No No
No
No
No
No
Space heating
Energy efficiency
class 35°C (Low
temp. app.)
-
A++ A++ A++
A++
A++
A++
A++
Space heating
Energy efficiency
class 55°C (Medium
temp. app.)
- A++ A++ A++
A++
A++
A++
A++
Prated (declared
heating capacity) @
10°C
[kW]
10 12 14
16
12
14
16
Seasonal space
heating efficiency (ηs
)
[%]
162 166 173
167
175
168
164
Annual energy
consumption
[kWh] 4,896 6,312 6,630
7,957
5,544
6,551
8,002
Prated (declared
heating capacity) @
10°C
[kW] 11 11 13
14
11
13
14
Seasonal space
heating efficiency (ηs
)
[%]
129 129 129
125
131
128
126
Annual energy
consumption
[kWh] 7,025 7,025 8,550
8,973
6,757
8,291
9,172
(A) condition
(-7°C)
Pdh (declared heating
capacity)
[kW] 9.1 11.4 12.8
13.5
10.6
12.0
12.0
COPd (declared
COP)
-
2.74 2.92 2.78
2.78
2.83
2.66
2.65
Cdh(degradation
coefficient)
- 0.90 0.90
0.90
0.90
0.90
0.90
0.90
Pdh (declared heating
capacity)
[kW] 5.3 6.7 7.8
9.0
6.6
7.2
8.6
COPd (declared
COP)
-
4.10 4.25 4.09
3.99
4.08
3.97
3.97
Cdh(degradation
coefficient)
- 0.90 0.90 0.90
0.90
0.90
0.90
0.90
Pdh (declared heating
capacity)
[kW] 3.5 4.4 4.8
6.1
4.4
4.9
5.6
COPd (declared
COP)
- 5.90 6.42 6.12
6.12
6.22
6.36
6.03
Cdh(degradation
coefficient)
- 0.90 0.90 0.90
0.90
0.90
0.90
0.90
Pdh (declared heating
capacity)
[kW]
1.4 2.0 3.1
3.1
3.7
3.8
4.0
COPd (declared
COP)
- 4.40 6.48 8.83
7.84
9.37
9.00
8.54
Cdh(degradation
coefficient)
- 0.90 0.90 0.90
0.90
0.90
0.90
0.90
Average climate (Design temperature = –10°C)
Product fiche 1
Heat pump space heater
Indoor unit sound power (*)
Outdoor unit sound power (*)
off peak operation function integrated
in Heat pump
Space heating
35°C
Space heating
55°C
Part load conditions space heating average climate low temperature application
(B) condition
(2°C)
(C) condition
(7°C)
(D) condition
(12°C)
A++ A++
A++ A++
5 7
176
178
2,143 2,989
7 7
126 126
4,228 4,228
4.1 5.80
2.85 2.80
0.90
0.90
2.4 3.6
4.53 4.18
0.90 0.90
1.7 2.3
6.08 6.39
0.90 0.90
1.3
1.4
8.92 9.24
0.90 0.90
MHC-
V16W/D2
N1
/
68
0
No
A++
A++
9
163
4,377
9
127
5,558
7.8
2.45
0.90
4.9
3.76
0.90
3.1
6.39
0.90
1.5
8.50
0.90

Table of Contents