57
unit
MHC-
V5W/D2
N1
MHC-
V7W/D2
N1
MHC-
V10W/D2
N1
MHC-
V12W/D2
N1
MHC-
V14W/D2
N1
MHC-
V16W/D2
N1
MHC-
V12W/D2
RN1
MHC-
V14W/D2
RN1
MHC-
V16W/D2
RN1
Tol (temperature
operating limit)
[°C]
-10 -10 -10 -10 -10 -10 -10
Pdh (declared heating
capacity)
[kW]
9.8 10.7 11.8 11.6 10.9 10.8 11.0
COPd (declared
COP)
-
2.48 2.60 2.59 2.38 2.47 2.41 2.36
WTOL (Heating wate
r
Operation Limit)
[°C]
49 49 49 49 49 49 49
Tblv [°C]
-10 -7 -8 -6 -7 -7 -5
Pdh (declared heating
capacity)
[kW]
9.8 11.4 13.0 13.9 10.6 12.0 13.0
COPd (declared
COP)
-
2.48 2.92 2.84 2.80 2.83 2.66 2.90
Supplementar
y
capacity at
P_design
Psup (@Tdesignh: –
10°C)
[kW]
0 2.1 2.2 4.8 1.1 2.7 5.2
(A) condition
(-
7°C)
Pdh (declared heating
capacity)
[kW]
10.0 10.0 12.0 12.3 9.7 11.6 11.7
COPd (declared
COP)
-
2.01 2.01 2.06 2.02 2.00 2.02 1.99
Cdh(degradation
coefficient)
-
0.90 0.90 0.90 0.90 0.90 0.90 0.90
Pdh (declared heating
capacity)
[kW]
6.3 6.3 7.4 7.9 6.2 7.5 7.8
COPd (declared
COP)
-
3.18 3.18 3.12 3.05 3.21 3.10 3.02
Cdh(degradation
coefficient)
-
0.90 0.90 0.90 0.90 0.90 0.90 0.90
Pdh (declared heating
capacity)
[kW]
4.0 4.0 4.7 5.1 4.1 4.7 5.1
COPd (declared
COP)
-
4.54 4.53 4.68 4.57 4.67 4.68 4.70
Cdh(degradation
coefficient)
-
0.90 0.90 0.90 0.90 0.90 0.90 0.90
Pdh (declared heating
capacity)
[kW]
2.6 2.6 2.1 2.1 3.0 2.8 2.8
COPd (declared
COP)
-
5.37 5.37 4.82 4.77 5.68 5.20 5.28
Cdh(degradation
coefficient)
-
0.90 0.90 0.90 0.90 0.90 0.90 0.90
Tol (temperature
operating limit)
[°C]
-10 -10 -10 -10 -10 -10 -10
Pdh (declared heating
capacity)
[kW]
10.9 10.9 11.0 10.2 11.5 11.7 10.6
COPd (declared
COP)
-
1.76 1.76 1.75 1.68 1.76 1.77 1.78
WTOL (Heating wate
r
Operation Limit)
[°C]
49 49 49 49 49 49 49
Tblv [°C]
-7 -7 -7 -7 -7 -7 -6
Pdh (declared heating
capacity)
[kW]
10.0 10.0 12.0 12.3 9.7 11.6 12.1
COPd (declared
COP)
-
2.01 2.01 2.06 2.02 2.00 2.02 2.09
Supplementar
y
capacity at
P_design
Psup (@Tdesignh: –
10°C)
[kW]
0.4 0.4 2.6 3.7 0 1.5 3.7
Product fiche 2
Heat pump space heater
(B) condition
(2°C)
(E) Tol
(temperature
operating limit
)
(F) Tbivalent
temperature
Part load conditions space heating average climate medium temperature application
(C) condition
(7°C)
(D) condition
(12°C)
(E) Tol
(temperature
operating limit
)
(F) Tbivalent
temperature
-10 -10
4.2 6.3
2.62 2.61
49 49
-7 -7
4.1 5.8
2.85 2.80
0.5 0.3
5.8 5.8
1.97 1.97
0.90 0.90
3.7 3.7
3.06 3.06
0.90 0.90
2.6 2.6
4.46 4.46
0.90 0.90
1.3 1.3
5.65 5.65
0.90 0.90
-10 -10
6.6 6.6
1.71 1.72
49 49
-7 -7
5.8 5.8
1.97 1.97
0 0
MHC-
V9W/D2
N1
-10
7.5
2.39
49
-7
7.8
2.45
1.4
7.7
1.98
0.90
4.9
3.02
0.90
3.2
4.67
0.90
1.4
6.16
0.90
-10
7.0
1.78
49
-7
7.7
1.98
1.7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MHC-V14W/D2RN1 and is the answer not in the manual?

Midea MHC-V14W/D2RN1 Specifications

General IconGeneral
BrandMidea
ModelMHC-V14W/D2RN1
CategoryHeat Pump
LanguageEnglish

Related product manuals