Provides instructions for safe lifting and handling of the outdoor unit.
Guidelines for installing the unit in cold climates to prevent wind and snow damage.
Recommendations for positioning the unit to avoid direct sunlight impact on thermistors.
Provides detailed dimensions for 4/6 kW and 8/10 kW outdoor units.
Details requirements for ground strength, level installation, and bolt usage.
Specifies clearance needed for stacked and multiple-row installations.
Covers requirements for refrigerant pipe length, bends, and height difference.
Details methods for checking pipe joints for refrigerant leaks using soap water or detector.
Specifies wire diameters and circuit breaker requirements for unit safety.
Explains the unit's protection mechanisms activated during cooling or heating.