MCAC-UTSM-2008-05 Installation of Outdoor Unit
Installation 83
3. Installation of Outdoor Unit
Caution:
1) Keep this unit away from direct radiation of the sun or other heaters. If unavoidable, please cover it with
a shelter.
2) In places near coast or with a high attitude where the wind is strong, please install the outdoor unit
against the wall to ensure normal performance.
3) Use a baffle when necessary.
4) In the case of extremely strong wind, please prevent the air from flowing backwards into the outdoor
unit.
5) Locate the outdoor unit as close to the indoor unit as possible.
6) The minimum distance between the outdoor unit and obstacles described in the installation chart does not
mean that the same is applicable to the situation of an airtight. Leave open two of three directions M, N, P.
3.1 Necessary Room for Installation and Maintenance.
If possible, please remove the obstacles nearby to prevent the performance from being impeded by too little
of air circulation. Leave open two of the three directions (M, N, P).