www.mideaaircon.com 26
9.
Power Connection Options
Appropriate power cord accessory kit is determined by the voltage and amperage of the branch circuit.
The unit does not come with a power cord (or hardwire kit). An accessory power cord must be ordered
to connect the unit to an outlet. If the unit is to be hardwired, an accessory hardwire kit must be
ordered.
NOTE: For 265V units, if a power cord is selected, it must plug into the 265V subbase accessory.
Cord-connected Units
The 240V field supplied outlet must match the plug for the standard 208/230V units and be within reach
of the service cord. The standard cord-connected 265V units require an accessory electrical subbase
for operation.
Power Cord Protection
The power cord for 230/208v units provide power cord fire protection. The unit’s power automatically
disconnects when unsafe conditions are detected. Power to the unit can be restored by pressing the
reset button on plug. Upon completion of unit installation for 230/208V models, an operational check
should be performed using the TEST/RESET buttons on the plug.
NOTE: The 265V models do not incorporate this feature as they require use of the electrical subbase
accessory. Our subbase accessory is being developed.
The appearance of the power plug will differ depending on the supplier.