between temperature
sensor and PCB. It is
properly connected?
Measure the resistance
value of the sensor.
10.
Troubleshooting
10.1
Error Display
Open or short circuit of T1 temperature sensor
Open or short circuit of T2 temperature sensor
Open or short circuit of T3 temperature sensor
Open or short circuit of T4 temperature sensor
Open or short circuit of T5 or T6 temperature sensor
Temperature is lower than display range (32°F)
Temperature is higher than display range (99°F)
Communication malfunction between main control board and display board
Drive-by-wire control failure
10.2
Troubleshooting
10.2.1
Open circuit or short circuit of temperature sensor diagnosis and solution (AS/E5/CS/oS/HS).
Error Code:
AS/ES/CS/OS/HS
Malfunctioning conditions:
If the sampling voltage is lower than 0.06V or higher than
4.94V, the LED will display the failure.
●
Faulty sensor
●
Faulty PCB
Troubleshooting:
No
Yes
No
Yes
Replace indoor main PCB.
Correct the connection.
Replace the sensor.