8. Electronic function
8.1 Abbreviation
T1: Indoor room temperature
T2: Coil temperature of evaporator
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
T5: Compressor discharge temperature
8.2 Display function
8.2.1 Icon explanation on indoor display board.
Run indication lamp:
This lamp illuminates when the air conditioner is in operation.
Auto indication lamp:
Lights up during the Auto operation.
Timer indication lamp:
Lights up during Timer operation.
Defrost indication lamp:
This indicator illuminates when the air conditioner starts
defrosting automatically or when the anti-cold wind function is
activated in heating operation.
Digital display indication
lamp:
Displays current setting temperature or malfunction codes when
the air conditioner is in operation.