EasyManuals Logo

Midea MS9A-07HRN1-QB6 User Manual

Midea MS9A-07HRN1-QB6
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
36
8.4 Operation Modes and Functions
8.4.1 Fan mode
(1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled, and no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates the same as in cooling mode.
(5) Auto fan:
29
28
High
Low
25
Medium
8.4.2 Cooling Mode
8.4.2.1 Compressor running rules
Once the compressor starts up, it will follow the below rules:
When indoor room temp.T1 is lower than Tn, the compressor and outdoor fan will shut off. When T1 is
higher than Tm, the compressor and outdoor fan will start up.
Tm
On
Off
Tn
Tm=Ts+1, Tn=Ts-1 for MS9A-24HRN1-QB8W models
Tm=Ts+1, Tn=Ts for other models.
8.4.2.2 Outdoor fan running rules
The outdoor units have single fan speed. The outdoor fan will run following the action of the

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MS9A-07HRN1-QB6 and is the answer not in the manual?

Midea MS9A-07HRN1-QB6 Specifications

General IconGeneral
BrandMidea
ModelMS9A-07HRN1-QB6
CategoryAir Conditioner
LanguageEnglish

Related product manuals