9. Troubleshooting 
9.1 Indoor unit error display 
For MS9A-09HRN1-QB8, MS9A-09HRN1-QC2(2T0032300908), MS9A-11HRN1-QB8, 
MS9A-16HRN1-QB8(A): 
Display  LED STATUS 
E1  EEPROM error 
E2  Zero crossing signal detection error 
E3  Indoor fan speed has been out of control 
E4  Over current protection of the compressor occurs 4 times 
E5  Open circuit or short circuit of room temperature sensor 
E6  Evaporator temperature sensor open circuit or short circuit   
 
For 21k,24k models: 
Display  LED STATUS 
E1  EEPROM error 
E4  Over current protection of the compressor occurs 4 times 
E5  Indoor room temperature sensor T1 open circuit or short circuit 
E6  Evaporator coil temperature sensor T2 open circuit or short circuit   
E7  Condenser coil temperature sensor T3 open circuit or short circuit 
E9  Indoor / outdoor units communication error 
 
 
For other models 
Timer lamp  Failure 
☆  X  Indoor fan speed has been out of control 
☆  O  The T1 or T2 sensor is open circuit or short circuit 
X  ☆ 
Over current protection occurs 4 times(for 
MS9A-12HRN1-QC2 with BOM code 220032402100,it 
doesn’t have this kind of protection) 
O  ☆  EEPROM error 
☆  ☆  Zero crossing signal detection error 
  O(light)     X(off)   ☆(flash)