9.2.6 Indoor unit and outdoor unit communication malfunction diagnosis and solution
Yes
Yes
Measure Vs, is it moving alternately
with positive value?
(Vs is the voltage between N and S of
outdoor unit. The red pin of
multimeter connects with N port, the
black pin of multimeter connects with
S port.)
Yes
Power off, then turn on the unit 5 seconds
later(reconnect the power wire).Is the error
still displaying after several minutes?
No
Yes
Change the outdoor main PCB.
Power on. Is the error extinguished?
Check all the wirings between indoor and
outdoor, indoor main PCB and outdoor main
PCB following the wiring diagram. Are all
the wirings connected correctly?
Is the wiring to the indoor main
PCB connected correctly?
Change the indoor main PCB.
Yes
Change the outdoor main PCB.
No
Is the wiring to the outdoor main
PCB connected correctly?
Power on. Is the error extinguished?
Change the indoor main PCB.
No