Service manual 
42 
 
 
13. Troubleshooting 
13.1   Indoor Unit Error Display   
Display LED STATUS 
E0 EEPROM error 
E1  Indoor / outdoor units communication protection 
E2 Zero-crossing examination error 
E3  Fan speed beyond control 
E5  Open or short circuit of outdoor temperature sensor 
E6  Room temperature or evaporator temperature sensor open or short circuit of 
P0 Module protection 
P1  Over voltage or too low voltage protection 
P2  Compressor top protection against temperature 
P3  Outdoor low temp. protection 
P4  Inverter compressor drive error 
 
Note: E4:    Reserved function 
 
13.1.1 
 
Display LED STATUS 
E0  EEPROM parameter error 
 
 
           
 
 
 
    
 
13.1.2 circuit or software error on indoor cortrol board 
 
Display LED STATUS 
E1  Indoor / outdoor units communication protection 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Replace the control board of indoor 
Circuit or software error on indoor control board