Mission On-off DM16-01.01.21en
34 Service manual
9. Electronic function
9.1 Abbreviation
T1: Indoor room temperature
T2: Coil temperature of evaporator
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
T5: Compressor discharge temperature
9.2 Display function
7.2.1 Icon explanation on indoor display board.
Digital display:
Displays the temperature settings when the air conditioner is operational.
Displays the room temperature in FAN mode.
Displays the self-diagnostic codes.
Dispalys ‘
for three seconds when Timer ON, Fresh, Swing, Turbo or Silence feature is activated.
Dispalys ‘
for three seconds when Timer OFF is set. Fresh, Swing, Turbo or Silence feature is
cancelled.
Dispalys ‘
under deforsting operation.
Dispalys ‘
when anti-cold air feature is activated under heating mode.

Related product manuals