35
9.3.4 Fan speed has been out of control diagnosis and solution(E3)
Error Code
E3/F5
Malfunction decision
conditions
When indoor fan speed keeps too low (300RPM) for certain time,
the unit will stop and the LED will display the failure.
Supposed causes Wiring mistake
Fan assy faulty
Fan motor faulty
PCB faulty
Trouble shooting:

Table of Contents