Special Functions
Improving the quality of indoor air is one of the purposes of an air conditioner. This air
conditioner is equipped with IONIZER. With the anions generated by IONIZER, the air
circulation of the air conditioner fills the room with refreshing, natural and healthy air.
CLEAN AIR Function
O
8 C HEATING
O
In heating operation, the preset temperature of the air conditioner can be as low as 8 C,
which keeps the room temperature steady at 8 C in winter.
O
FOLLOW ME Function
To activate the FOLLOW ME feature, point the remote control towards the indoor unit
receiver and press the FOLLOW ME button. The remote display shows the actual
temperature at its location. The remote control will send this signal to the air conditioner
at 3 minutes intervals until the FOLLOW ME button is pressed again. If the unit does not
receive any FOLLOW ME signal during any 7 minute interval, the FOLLOW ME mode will
be deactivated automatically.
The remote control serves as a remote thermostat, allowing for precise
temperature control at its location.
SELF CLEAN Function
This function is used after the Shut Down of cooling operation to clean the Evaporator
and keep it fresh for the next operation.
The unit will operate as following sequence : FAN ONLY mode at LOW fan speed,
HEATING mode with LOW fan speed (applicable to cooling & heating models only),
FAN ONLY mode, stop operation, turn off.
NOTE:
This function is only available under COOL (AUTO COOL, FORCED COOL) and DRY.
Before selecting the function, it is recommended to run the air conditioner under Cooling
Operation for about half an hour. Once the SELF CLEAN function is activated, all TIMER
settings will be cancelled.
When the SELF CLEAN button on the remote control is pressed again during the SELF
CLEAN operation, the operation will stop and the unit will turn off automatically.
REFRIGERANT LEAK DETECTION
With this New Technology, ‘EC’ will appear in the display area when the outdoor unit
detects refrigerant leakage.
6
11. Connecting pipe
12. Connecting cable
13. Stop valve
Outdoor Unit
NOTE:
All the pictures in this manual are for
explanation purposes only. Your air conditioner
may be slightly different from illustration.
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille (outside)
6. Horizontal air flow grille (inside)
7. Vertical air flow louver
8. Display panel
9. Manual control button and receiver
10. INTELLIGENT EYE (on some models)
Indoor Unit
Parts Names
TIMER indication lamp
Lights up during Timer Operation.
DEFROST indication lamp
(Enabled on cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm
air control feature is activated in heating
operation.
TEMPERATURE indication lamp
Displays the temperature settings when the
air conditioner is operational.
Displays the malfunction code.
Displays the actual room temperature on
Fan only mode.
11
3
10
2
1
12
13
4
5
6
7
9
8
ION indication lamp
Lights up when CLEAN AIR feature
(IONIZER) is activated.
INTELLIGENT EYE indication lamp
Lights up during Intelligent eye operation
except when the machine is defrosting.
This indication lamp continues flashing
when the unit detects human activity.
.
Display Panel
Manual button and receiver
(at the bottom of the machine)
INTELLIGENT EYE DETECTOR
With the built-in infrared sensor, the unit can detect the presence of humans in the room. If the
unit detects no human activity continuously for 30 minutes, it will automatically enter standby
(monitor) status in order to save power consumption. The unit will automatically start and
resume operation when human activity is sensed again.
LOUVER ANGLE MEMORY Function
Within the scope of safety angle, the unit will memorize the open angle of horizontal
louver. If it exceeds this, it will memorize the boundary of safety angle. In the
following circumstances, it will return to standard angle:
1) The turbo or manual control button has been pressed;
2) The machine has been unplugged and then plugged in again.
We strongly suggest that the open angle of the horizontal louver should not be set too
small in case condensed water forms and drops from the horizontal louver.