OPERATING INSTRUCTIONS
Airflow Direction Control
Adjust the airflow direction properly, otherwise it might
cause discomfort or cause uneven room temperature.
Adjust the horizontal louver using the remote control.
Adjust the vertical louver manually (for models without
motorised louver function) or using the remote control.
To set the vertical airflow (UP - DOWN) direction:
Perform this function while the unit is in operation. Use
the remote control to adjust the air flow direction. The
O
horizontal louver can be moved at a range of 6 for each
press, or swing up and down automatically. Please refer
to the ‘REMOTE CONTROL MANUAL’ booklet for details.
To set the horizontal airflow (LEFT - RIGHT) direction:
Move the Deflector Rod manually to adjust the air flow
in the direction you prefer. (FOR MODELS WITHOUT
MOTORISED HORIZONTAL LOUVER FUNCTION)
IMPORTANT: Do not put your fingers into the panel of
blower and suction side. The high-speed fan inside may
cause injury.
For some models, the vertical louver can be adjusted
by using the remote control. Please refer to the
‘REMOTE CONTROL MANUAL’ for details.
Do not operate the air conditioner for long periods with
the airflow direction set downward in cooling or
dehumidifying mode. This may cause condensation on
the surface of the horizontal louver causing moisture to
drop onto the floor or on furnishings.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds. Please wait.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too greatly restricted area of airflow.
Do not move the horizontal louver manually, otherwise
the horizontal louver will be out of sync. Please cease
operating, unplug power for a few seconds, then restart
the air conditioner.
Do not operate unit with horizontal louver in closed
position.
CAUTION
Manual operation can be used temporarily in case the remote control is disabled or the unit
requires maintenance.
OPERATING INSTRUCTIONS
Manual Operation
NOTE: This manual does not include Remote Control Operations. Please see the
‘Remote Control Manual’ booklet packed with the unit for details.
Operating Temperatures
Manual Control Button
Range
Range
Deflector Rod
Mode
Temperature
Room temperature
Outdoor temperature
1. Optimum performance will be achieved within these operating temperatures. If air
conditioner is used outside of the above conditions, certain safety protection features
might come into operation and cause the unit to function abnormally.
2. Room relative humidity should be less than 80%. If the air conditioner operates in excess
of this figure, the surface of the air conditioner may attract condensation. Please set the
vertical airflow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
NOTE:
Cooling operation
Heating operation Drying operation
17 62
-15 50 5 122
For the models with low
temperature cooling system
0 50
32 122
30 86
-15 30
5 86
10 50
0 50
32 122
The Manual Control Button is on the bottom
of the unit as shown in the picture.
One press of the Manual Control Button will
lead to the FORCED AUTO operation.
If the Manual Control Button is pressed twice
within five seconds, the unit will operate under
FORCED COOL operation.
This button is used for testing purposes only.
Please DO NOT USE it.
To restore the remote control operation, use
the remote control directly.
CAUTION:
1
3
2
NOTE: The unit must be turned off before
operating the Manual Control Button. If the
unit is operating, continue pressing the Manual
Control Button until the unit is switched off.