10. Compressor
10.1 Compressor on and off control specifications
1.1 When one of the following conditions is met, the compressor stops:
1) Measured temperature in refrigerator chamber Shutdown temperature of refrigerator
chamber
2) Enter defrosting cycle
3) The compressor runs continuously for more than 3 hours, will stop at least 5 minutes
1.2 When compressor shutdown time has been more than 5 min, one of the following conditions is
met, the compressor starts up:
1) Measured temperature in refrigerator chamber Start up temperature of refrigerator
2) Refrigerator is set to forced cooling mode
When 1.1 and 1.2 are not satisfied, the compressor maintains the original state