EasyManua.ls Logo

Midea US-KC41Y1/N1-N1(I6) - User Manual

Midea US-KC41Y1/N1-N1(I6)
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Website: www.mideaaircon.com
Service Manual
AIR CONDITIONER
Portable Type
N portable (AHAM
standard)
MPN-05CRN1-BH2(H)
US-KC15Y1/N1-N(H2H)
MPN-08CRN1-BH2(H)
US-KC23Y1/N1-N(H2H)
MPN-12CRN1-BH9(H)
US-KC35Y1/N1-N(H9H)
N portable (ASHRAE
standard)
MPN-05CRN1-BH9
US-KC15Y1/N1-N(H9)
MPN-08CRN1-BH9
US-KC23Y1/N1-N(H9)
MPN-085CRN1-BH9
US-KC25Y1/N1-N(H9)
MPN-10CRN1-BH9
US-KC30Y1/N1-N(H9)
MPN-12CRN1-BH9
US-KC35Y1/N1-N(H9)
MPN-14CRN1-BI6
US-KC41Y1/N1-N(I6)
N1 portable (AHAM
standard)
MPN1-08CRN1-BH2(H)
US-KC23Y1/N1-N1(H2H)
MPN1-09CRN1-BH2(H)
US-KC26Y1/N1-N1(H2H)
MPN1-10CRN1-BH2(H)
US-KC30Y1/N1-N1(H2H)
MPN1-12CRN1-BH9(H)
US-KC35Y1/N1-N1(H9H)
N1 portable (ARI
standard)
MPN1-08CRN1-BH9
US-KC23Y1/N1-N1(H9)
MPN1-10CRN1-BH9
US-KC30Y1/N1-N1(H9)
MPN1-12CRN1-BH9
US-KC35Y1/N1-N1(H9)
MPN1-14CRN1-BI6
US-KC41Y1/N1-N1(I6)
N series
N1 series
Question and Answer IconNeed help?

Do you have a question about the Midea US-KC41Y1/N1-N1(I6) and is the answer not in the manual?

Summary

Safety Precaution

Installation

Safety instructions for electrical work, product handling, and installation environment.

Caution

Precautions regarding refrigerant leakage, draining, installation level, and noise.

Operational

Guidelines for product operation, cleaning, and battery handling.

Out Dimension

Display

MODE Select Button

Selects the operating mode (AUTO, COOL, DRY, FAN, HEAT).

TIMER Button

Initiates AUTO ON/OFF time program.

POWER Button

Switches the unit on/off.

SLEEP Button

Initiates the SLEEP operation.

FAN Button

Controls fan speed (LOW, MED, HI).

ION Button (Optional)

Activates ion generator for air purification.

UP and DOWN Buttons

Adjusts temperature or timer settings.

LED Display

Shows temperature, timer settings, and error codes.

Error Codes

Lists common error codes (E1, E2, P1) and their remedies.

SWING Button

Controls louver angle and initiates auto swing.

Refrigerant Cycle Diagram

PCB Drawing & Wiring Diagram

Specification

Installation Detail

Position Requirement for Installation

Specifies location requirements, clearance, and placement restrictions.

Preparation Work

Instructions for preparing and connecting the exhaust hose.

Installation in a Double-Hung Sash Windows

Steps for installing the unit in double-hung sash windows.

Installation in a Sliding Sash Windows

Steps for installing the unit in sliding sash windows.

Feature

Basic Test Procedure

Defective Compressor

Tests for compressor continuity, grounding, and efficiency.

Sealed Refrigeration System Repairs

Procedures for recovering, evacuating, and charging refrigerant.

Fan Motor

Information and testing procedures for the fan motor.

Capacitor

Explains the function and testing of capacitors for motors.

Characteristic of Temperature Sensor

Trouble Shooting

No Power Display or Button Failure

Troubleshooting for units with no power display or unresponsive buttons.

Remote Control Failure

Diagnosing and fixing issues with the remote control.

Fan Motor Runs Intermittently

Addressing intermittent fan motor operation.

Compressor Stops Instantly After Startup

Troubleshooting compressor startup issues.

Fan Motor Will Not Run

Steps to diagnose why the fan motor is not running.

Fan Motor Noise

Identifying and resolving fan motor noise issues.

Compressor Not Running With Fan

Troubleshooting when the fan runs but the compressor does not.

Excessive Noise

Addressing general excessive noise from the unit.

Water Full Alarm

Steps to resolve the water full alarm indicator.

Poor Cooling or Heating

Diagnosing poor cooling or heating performance.

No Cooling or Heating

Troubleshooting steps for units that do not cool or heat.

Unit Starts and Stops Frequently

Diagnosing frequent unit start/stop cycles.

Exploded View & Parts Listing: MPN-10 CRN1-BH9

Exploded View & Parts Listing: MPN1-08 CRN1-BH9

Exploded View & Parts Listing: MPN1-10 CRN1-BH9

Overview

This document provides a comprehensive service manual for Midea portable air conditioners, covering models in both the N and N1 series. It includes safety precautions, installation details, technical specifications, operational features, and troubleshooting procedures.

Function Description

The Midea portable air conditioner is designed to provide cooling, heating (for some models), dehumidification (dry mode), and fan-only operation. It is a consumer air conditioner, not a precision refrigerant system, and is intended for general room climate control. The unit operates by drawing in room air, processing it through a refrigeration cycle, and discharging conditioned air. It features a single louver for air direction and a straight condenser for efficient heat exchange. The unit is designed with a "no water tank" feature, implying an advanced shower system or self-evaporating mechanism for condensate management.

Important Technical Specifications

The manual details specifications for various models, including cooling capacity (Btu/H), Energy Efficiency Ratio (EER), current draw (Amps Cool), power consumption (Watts Cool), compressor type, refrigerant type (R410A), refrigerant amount (oz/g), design pressure (Psig), and air flow (M³/H(CFM)).

For example, the MPN-05CRN1-BH2(H) model has:

  • Cooling: 5000 Btu/H
  • EER: 8.2
  • Amps (Cool): 5.4 A
  • Watts (Cool): 600 W
  • Compressor: 39A121AA&54KA
  • Refrigerant: R410A, 10.2/290 oz/g
  • Design Pressure: 550/340 Psig
  • Air Flow: 360/310/270 M³/H(CFM)

Another example, the MPN1-12CRN1-BH9 model has:

  • Cooling: 12000 Btu/H
  • EER: 8.9
  • Amps (Cool): 11.9 A
  • Watts (Cool): 1340 W
  • Compressor: EA103M1C-1DZDU1
  • Refrigerant: R410A, 15.2/430 oz/g
  • Design Pressure: 550/340 Psig
  • Air Flow: 470/430/370 M³/H(CFM)

Compressors are single-phase, 115 or 230/208 volt, permanent split capacitor type, using a running capacitor across the start and run terminals. They are internally spring-mounted and externally mounted on rubber isolators.

Usage Features

The portable air conditioner offers several user-friendly features:

  • Mode Selection: Users can select from AUTO, COOL, DRY, FAN, and HEAT (for cooling-only models, HEAT is not available).
  • Timer Function: Allows setting AUTO ON start time and AUTO OFF stop time programs.
  • Temperature Adjustment: Temperature settings can be adjusted in 1°C/2°F increments within a range of 17℃ (62°F) to 30℃ (88℉). The timer setting can be adjusted from 0 to 24 hours. The display can switch between Fahrenheit and Celsius by pressing and holding the Up and Down buttons simultaneously for 3 seconds.
  • Fan Speed Control: Three fan speeds are available: LOW, MED, and HI.
  • Sleep Mode: Initiates a SLEEP operation for comfortable nighttime use.
  • ION Button (optional): Activates an ion generator to remove pollen and impurities from the air.
  • Swing Function (optional): Allows the louver to swing up to a 6° angle per press, or continuous auto-swing by pressing the button for more than 2 seconds.
  • Turbo Cooling Function: Provides rapid cooling.
  • Flexible Air Exhaust: Facilitates easy installation and exhaust hose management.
  • Advanced Shower System: Likely refers to an efficient condensate management system, possibly self-evaporating.
  • Follow Me Function: Allows the unit to sense the temperature at the remote control's location for more precise comfort.
  • 24-hour On/Off Timer: Provides flexibility in scheduling operation.
  • No Water Tank Design: Eliminates the need for manual condensate draining in most operating conditions.

Maintenance Features

The manual outlines several maintenance and troubleshooting procedures:

  • Safety Precautions: Emphasizes professional installation, avoiding self-repair, caution with sharp edges, ensuring proper power cable handling, and not operating with flammable gases nearby. It also advises disconnecting power during cleaning or prolonged non-use.
  • Installation: Requires a flat, spacious location with a minimum clearance of 30cm from walls or obstacles. The plug must be accessible, and wiring should comply with national rules. Detailed instructions are provided for installing the exhaust hose and window panel kits for both double-hung and sliding sash windows.
  • Cleaning: Recommends using a soft cloth for cleaning and avoiding harsh detergents. Air filters should be cleaned every two weeks or more often if necessary.
  • Compressor Testing: Procedures for checking compressor continuity (C-S, C-R, R-S terminals) and for ground faults using an ohmmeter. It also describes how to check for compressor inefficiency due to faulty valves by monitoring high and low side pressures and temperature difference across the coil.
  • Overload Protection: Explains external and internal overload mechanisms and how to test them for continuity.
  • Refrigerant System Repairs: Detailed steps for sealed refrigeration system repairs, including refrigerant recovery, component replacement (compressor, condenser, evaporator, capillary tube, filter drier), leak testing with dry nitrogen and halogen leak detectors, evacuation to a deep vacuum (200 microns or less), and precise refrigerant charging. It also covers special procedures for compressor motor burnout, including flushing the system.
  • Fan Motor Testing: Instructions for checking the fan motor capacitor and testing motor speeds by applying power to specific wires.
  • Capacitor Testing: Describes how to visually inspect capacitors for damage and how to test them using an ohmmeter for continuity and deflection. A table of temperature sensor resistance values (Temp.°C vs. Resistance KΩ) is provided for diagnostic purposes.
  • Troubleshooting Guide: A comprehensive table of common problems, possible causes, and remedies, covering issues like no power, remote control failure, fan motor not running or making noise, compressor not running, excessive noise, water full alarm, and poor cooling/heating performance. This includes checks for power supply, transformer, PCBs, batteries, fan motor bearings, wiring, temperature settings, and refrigerant levels.

Midea US-KC41Y1/N1-N1(I6) Specifications

General IconGeneral
BrandMidea
ModelUS-KC41Y1/N1-N1(I6)
CategoryAir Conditioner
LanguageEnglish

Related product manuals