Do you have a question about the Midmark UltraClave M11 and is the answer not in the manual?
Manual's scope, purpose, and intended use for installation, operation, and care.
Details the product's intended use in medical and dental settings for sterilizing heat-stable equipment.
Key safety guidelines for operating and maintaining the sterilizer to ensure staff and patient safety.
Defines DANGER, WARNING, CAUTION, and NOTE symbols and their meanings.
Specifies environmental conditions and precautions for transporting and storing the sterilizer.
Recommendations for sterilizer placement, including support surface and clearance requirements.
Procedure for safely moving the sterilizer to a new location, including cooling and draining.
Details voltage, frequency, and grounding requirements for safe electrical connection.
Details the function of displays and indicator lights for cycle status and alerts.
Explains how to select specific sterilization cycles like Unwrapped, Pouches, Liquids, and Packs.
Describes the function of main control buttons such as START, STOP, and ON/STANDBY.
Covers secondary controls like the printer, door handle, level indicator, and fill opening.
Covers guidelines for loading trays to ensure proper steam penetration and effective sterilization.
Details maximum recommended loads for trays, including handpieces and instruments.
Routine tasks for daily cleaning of external surfaces and door gasket.
Procedures for weekly cleaning of the sterilizer chamber and trays.
Monthly tasks including flushing the system and performing pressure relief valve checks.
Quarterly procedures for cleaning the door gasket and housing channel.
Table to identify and resolve common problems with possible causes and solutions.
List of error codes, their meanings, and recommended actions to resolve them.
Defines the warranty coverage for new Midmark products and components.
Specifies the duration of the warranty, measured from the date of delivery.
Lists conditions and situations not covered by the warranty, such as misuse or unauthorized repairs.
States that the sole remedy is repair or replacement of defective parts.
Clarifies that no other obligations or liabilities are authorized for Midmark.
Step-by-step instructions for physically installing the optional printer unit.
How to turn the printer on/off and advance paper using the rocker switch.
Guidance on loading a new paper roll into the printer.
Information on the printer's cartridge ribbon and when replacement is needed.
Instructions for removing an old ribbon and installing a new one.
Procedure for safely removing the paper roll from the printer.
Details the information printed by the unit for each program cycle.
| Frequency | 50/60 Hz |
|---|---|
| Number of Trays | 4 |
| Sterilization Temperature | 270°F (132°C) |
| Chamber Size | 11" diameter x 18" deep |
| Power Consumption | 1450 Watts |
| Overall Length | 23.8" |
| Overall Height | 17.8" |
| Standard Cycle Times | Varies depending on cycle type and load size |
| Heater | 5.5 kW |
| Reservoir Capacity | 5.5 gallons |
| Cycle Time | Varies depending on cycle type and load size |