89
Factory default
All parameters which have been altered can be reset to their default
settings. Control parameters and program settings are reset
separately.
Open the menu as follows:
Button
Additional settings
Factory default
Reset
Reset
No
Program settings only
No
Altered parameters are maintained.
Program settings only
All program settings are reset.
Programs saved on free memory locations remain unchanged.
All settings
All control parameters including dispensing quantities and water
hardness will be reset.
Select an option using the and arrow buttons.
Confirm your selection with OK.
By selecting All settings the machine is being restarted. After
restarting you are prompted to enter basic parameters, such as
language, date, time, water hardness etc. again.
Enter language, date, time etc..
Select the Drain program and press the Start/Stop button.
Once the Drain program is completed, all entries are saved and the
factory settings are restored.
Software version
You can use this menu to call up the software versions of individual
elements, e.g. when contacting Miele Service.
For more information see "Service".