Problem solving guide
74
Water inlet fault
Problem Possible cause and remedy
One of the following
messages appears in
the display:
Open stopcock The tap is turned off.
Turn on the tap fully.
Water intake Before rectifying the problem, you must:
Switch the dishwasher off with the button.
Water intake is restricted.
Turn on the tap fully and start the programme
again.
Clean the water inlet filter (see “Maintenance”).
The water pressure at the intake is lower than 50
kPa (0.5 bar).
Seek professional advice.
The following message
appears in the display
during the SolarSave
programme:
Intake temp. low
The intake water has not reached the required
temperature of 45°C (see “Water connection -
Connection to the water supply”).
Start the programme again.
If the fault message appears again, select a
different programme.