With a building under height of
820 mm the plinth height can be set
between 100 - 170 mm.
With a height > 100 mm a cutout for
ventilation must be provided in the
plinth (see "Appliance installation").
A building under height of 870 mm is
obtained by adjusting the appliance
feet. This increases the height of the
plinth, which, in this case, can be 150 -
220 mm.
With a height > 150 mm a cutout for
ventilation must be provided in the
plinth (see "Appliance installation").
A furniture front panel is required for
installing the appliance as an
integrated unit. If the appliance is
installed at the end of a run of kitchen
units, a furniture side panel may also be
required, depending on on-site
conditions.
The socket (9) should be freely
accessible and is best positioned to the
side of the appliance.