Supervisor level (programming mode)
26
Requirements for accessing supervisor level
- The appliance is switched on.
- The appliance door is open.
Accessing supervisor level
Touch and hold theStart/Stop sensor control and close the door.
TheStart/Stop sensor control flashes rapidly for 2seconds.
Continue touching theStart/Stop sensor control for at least 4seconds.
TheStart/Stop sensor control will light up constantly. This indicates that you have success-
fully accessed the supervisor level programming mode.
Release theStart/Stop sensor control.
If the illuminatedStart/Stop sensor control is not released again within 6seconds, the ap-
pliance will detect an accessing error or a door jam.
The maximum time for the access attempt is 10seconds. The attempt will then be can-
celled automatically.
Overview of supervisor level
If the pre-set values in the supervisor level are changed, the tumble dryer’s energy require-
ments may change.
Pro-
gramme
Designation Possible set
value
Standard
setting
Explanation
Drying level Cottons
= Damper3
= Damper2
= Damper1
= Standard
= Drier1
= Drier2
= Drier3
Drying level Minimum iron
= Damper3
= Damper2
= Damper1
= Standard
= Drier1
= Drier2
= Drier3
Cottons & Timed operation internal/ex-
ternal1
Heater bank temperature
– See “Heater bank temperature” table
Cottons & Timed operation internal/ex-
ternal1
Process air temperature
– See “Process air temperature” table
Cottons & Timed operation internal/ex-
ternal1
Drum drive running time in primary dir-
ection
– See table “Reversing cycle”
Cottons & Timed operation internal/ex-
ternal1
Drum drive running time in reverse dir-
ection