Installation
*INSTALLATION*
47
Burner ratings
Rated Heat Input
Burner Gas type Highest
setting
Lowest
setting
kW g/h kW
Normal burner HK Liquefied Petroleum gas (29mbar) 1.80 131 0.35
HK Town gas (10mbar) 1.80 – 0.35
Large burner HK Liquefied Petroleum gas (29mbar) 3.00 218 0.50
HK Town gas (10mbar) 3.00 – 0.50
Total HK Liquefied Petroleum gas (29mbar) 4.80 349 –
HK Town gas (10mbar) 4.80 – –