Electrical connection TE 5206
All electrical work must be carried out
only by a competent person in accord-
ance with local and national regulations.
This machine is supplied for connec-
tion to either:
440V ~3 phase supply 60Hz
without neutral
or
400V ~ 3 phase supply 50 Hz
without neutral
or
230V ~3 phase supply 60 Hz
without neutral
or
400V ~2 phase supply 50 Hz
(Electrical connection see Electrical
connection T 5206)
The machine is not convertible.
The voltage, rated load and fuse rating
are given on the data plate. Please en-
sure these match the site mains supply.
Connection should be made via a suit-
able isolator which complies with na-
tional and local regulations, and the
on/off switch should be easily ac-
cessible for servicing work. For extra
safety it is advisable to install a residual
current device with a trip current of
30 mA.
Electrical connection