22 23
Software update
• Insert the SD-card
• Turn on the machine
• Wait until the unit indicates
that the update is complete
• Turn off the machine and
remove the SD card
• The machine is now ready for
use
New software will be loaded into power source and all
connected units.
The software can be downloaded from http://migatronic.com to
an SD card. The file system of the SD card must be formatted to
FAT32.
IMPORTANT:
Save the software in the //MIGA_SW/SIGMA/ file structure.
Licence SW
If you purchase additional licences for programs or special
funtions, load the MigaLic.dat files like the software packages.
Note! Create a backup of the files.
The MigaLic.txt file contains information about licence number
and licences saved on SD card.
Connection and start-up
Wire inching forward/backward
When idling, wire inching can be activated by pressing one of the
keys or activated at the robot interface, if the MWF30 unit is used
in a robot setup.
Wire inching Sigma Select C
0.5/30 m/min 0.5/30 m/min
0.5/30 m/min
Wire inching remote control
Wire inching Sigma Select S