EasyManua.ls Logo

Migatronic SIGMA SELECT 300 COMPACT - BASIC Special Functions: Menu and Settings; User Menu and Parameter Settings; Gas Test and Flow Adjustment; IGC Calibration Process

Migatronic SIGMA SELECT 300 COMPACT
132 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
BASIC - Special functions
1. Open menu 2. Find menu selection 3. Select menu point
5 secs
Exit menu
Gas test
IGC calibration
(not all models)
Remote control
Water cooling
4. Set parameter 5. Save selected data 6. Exit menu
Parameters and menu selection
Press and hold the -key to open the user menu. Turn the
left control knob until the desired menu is displayed. Use
the right control knob to alter settings displayed in the right
display. Press the -key briefly to activate functions, such as
gas test.
Functions and parameters in the user menu:
Press the -key to exit the menu
GAS test
Press the -key to open and close the gas valve. If
an IGC kit is installed, it is possible to adjust the gas flow with
the right control knob.
IGC calibration
Visible only if IGC kit is installed.
Press the -key to start IGC calibration.
Water cooling
Visible only if water cooling unit is installed.
0: Water cooling OFF
1: Water cooling ON
Setting remote control
Use the right control knob to change the following
settings:
0: Disabled
1: Dialog torch (item no. 80100402)
2: Analogue remote control (item no. 78815029)

Related product manuals