EasyManua.ls Logo

MikroTik hAP ac

MikroTik hAP ac
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
hAP ac
hAP ac
The hAP is a simple home wireless access point. It is configured out of the box, you can simply plug in your internet cable and start using wireless internet.
We recommend you to set up a password to secure your device.
Safety Warnings
Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing
accidents.
Ultimate disposal of this product should be handled according to all national laws and regulations.
The Installation of the equipment must comply with local and national electrical codes.
This unit is intended to be installed in the rackmount. Please read the mounting instructions carefully before beginning installation. Failure to use the
correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system.
This product is intended to be installed indoors. Keep this product away from water, fire, humidity or hot environments.
Use only the power supply and accessories approved by the manufacturer, and which can be found in the original packaging of this product.
Read the installation instructions before connecting the system to the power source.
We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your
own risk!
In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.
It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling
requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik radio devices must be professionally installed.
This is a class A device. In a domestic environment, this product might cause radio interference in which case the user might be required to take adequate
measures.
Exposure to Radio Frequency Radiation: This MikroTik equipment complies with the FCC, IC, and European Union radiation exposure limits set forth for an
uncontrolled environment.This MikroTik device should be installed and operated no closer than 20 centimeters from your body, occupational user, or the
general public.
Quick Start
Connect your Internet cable to port 1, and local network devices to ports 2-5.
Set your computer IP configuration to (DHCP).
automatic
Wireless "access point" mode is enabled by default, connect to the wireless network that begins with "MikroTik".
The Default IP address from the local network is 192.168.88.1, open this address in your web browser to start the configuration. The username is
admin and there is no password.
The Ether5 port supports PoE output for powering other RouterBOARD devices.
We recommend clicking the "Check for updates" button and updating your RouterOS software to the latest version to ensure the best
performance and stability.
Choose your country, to apply country regulation settings, and set up your password on the screen that loads.
MikroTik mobile app

Other manuals for MikroTik hAP ac

Question and Answer IconNeed help?

Do you have a question about the MikroTik hAP ac and is the answer not in the manual?

MikroTik hAP ac Specifications

General IconGeneral
Flash memory16 MB
Internal memory128 MB
InternalNo
Product colorWhite
Security algorithms-
Operating relative humidity (H-H)-20 - 60 %
2.4 GHzYes
Frequency band2.412-2.462, 5.170-5.250, 5.725-5.835 GHz
Networking standardsIEEE 802.11a, IEEE 802.11ac, IEEE 802.11b, IEEE 802.11g, IEEE 802.11n
Ethernet LAN data rates10, 100, 1000 Mbit/s
Maximum data transfer rate500 Mbit/s
AC input voltage11 V
Power consumption (max)17 W
USB connector typeUSB Type-A
USB 2.0 ports quantity1
Ethernet LAN (RJ-45) ports5
Antenna gain level (max)2 dBi
Weight and Dimensions IconWeight and Dimensions
Depth29 mm
Width114 mm
Height137 mm

Summary

Safety Warnings

Product Disposal and Regulations

Handle product disposal according to national laws and regulations.

Installation Safety Codes

Ensure installation complies with local and national electrical codes.

Radio Frequency Radiation Exposure

Maintain 20cm distance from body due to FCC/IC/EU radiation limits.

Quick Start Guide

Powering the Device

Power Input Options

Accepts 11-57V DC via power jack or passive PoE on the first Ethernet port.

Connecting to PoE Adapter

Details on connecting the device to a PoE adapter for power.

Device Configuration

Alternative Connection Method

Use Winbox to connect via MAC address if IP connection is unavailable.

Network Booting for Recovery

Device can boot from the network via the first Ethernet port for recovery.

Hardware Ports and Features

Ethernet Ports Overview

Five Gigabit Ethernet ports with Auto MDI/X for network connections.

Integrated Wireless Features

Dual-band 2.4/5 GHz wireless with onboard antennas, max gain 2.5 dBi.

USB and SFP Ports

Includes a standard USB port and an SFP port for expansion.

PoE Output Port Functionality

Ether5 port provides PoE output with auto-detection and 0.7A support.

Buttons and Jumpers

Reset Button Functions

Describes functions like resetting configuration, CAP mode, and Netinstall.

RouterBOOT Loader Behavior

Button press before power loads backup RouterBOOT loader for debugging.

Product Specifications

Operating System Support

Supports RouterOS version 6; other OS not tested.

Important Notices

Frequency Band and Usage Restrictions

Notes restrictions on 5.470-5.725 GHz band and custom firmware requirements.

Outdoor Usage License Requirement

End-users require NTRA approval/license for outdoor usage.

Serial Number (EG) Product Limitations

Details frequency range and TX power limits for products with 'EG' serial numbers.

Firmware Lock Package Requirement

Ensure device has lock package for end-user equipment to prevent reconfiguration.

Health and Environmental Precautions

Environmental Disposal Guidelines

Separate device from household waste and dispose in designated sites.

Regulatory Compliance Statements

FCC Interference Statement

Equipment tested for Class A digital device limits, may cause interference if misused.

FCC and RF Radiation Exposure Limits

Complies with FCC limits; install and operate 20cm from body.

Innovation, Science and Economic Development Canada Compliance

Complies with Industry Canada RSS; subject to interference conditions.

Canadian Digital Apparatus Compliance

Class A digital apparatus compliance with Canadian ICES-003.

Indoor Use Restriction for 5150-5250 MHz

Device operation in 5150-5250 MHz band is for indoor use only.

IC Radiation Exposure Limits

Complies with IC limits; install and operate 20cm from body.

Eurasian Conformity Mark

Indicates compliance with Eurasian Customs Union requirements.

Norma Oficial Mexicana Compliance

Details frequency ranges and power limits for Mexican compliance.

Ukraine Communications Regulation

States compliance with Ukrainian radio equipment regulations and directives.

CE Declaration of Conformity

Declaration of compliance with EU Directive 2014/53/EU.

EU Frequency Bands Terms of Use

Outlines specific usage terms, power limits, and restrictions for EU frequency bands.

ETSI Radio Regulations Compliance

Device meets maximum WLAN transmit power limits per ETSI regulations.

Indoor Use Restriction for 5150-5350 MHz (ETSI)

WLAN function restricted to indoor use for 5150-5350 MHz band.

Related product manuals