NOTE: The fuel pump is a solenoid which is pulsed by the control box - be careful not to mount it on a board that may resonate. If
after installation the pump is n oisy re-locate it!
Installation of copper fuel line.
1. Fit the 1/4" to 3/16" reducer onto the standpipe.
2. Cut the required length of copper pipe from the amount supplied and
fit to the fuel cock.
3. Fit the straight connectors to the fuel pump. NOTE: 3 connectors are
fitted with 1 rubber olive and 1 copper olive and 1 straight connector is
fitted with 2 rubber olives.The connector with 2 rubber olives is to be
mounted between the fuel pump outlet and the fuel damper. Item 'A'.
4. Mount the fuel pump near the fuel cock at a 45
o
angle as shown. The
MX60 has a solenoid valve instead of the manual fuel cock which will
turn the fuel on automatically when the heater is operated.
5. Fix the remaining connector to the fuel inlet on the heater with the
rubber olive on the heater stub.
6. Cut the copper pipe to length, fit to the pump and the heater.
Length of pipe (max)
Standpipe to fuel pump:
Fuel pump to heater:
Head (max)
Bottom of fuel tank to pump centre:
Pump centre to heater centre:
(mm)
2000
5000
1000
<2000
- 6 -
5. Electrical.
The Mikuni heaters are supplied with simple plug together wiring looms.
MX40.
The MX40 is prewired on the s/s mounting plate. The only connections required are for the bat tery supply, the on/off switch and the
timer/thermostat.
Plug the 2 core power loom into the heater loom and run it directly to the battery. Fit the i nline 30 amp fuseholder and connect up to
the battery leaving the fuse out at the moment. Now mount the timer/thermostat and on /off switch and run the 3 core cable. Plug the
on/off switch in and connect the 2 x blue/yellow wires to the 'com' and 'n.o.' terminals on the timer/thermostat.
NOTE: Do not connect the live feed to the main power switch. If the power is turned off at the supply whilst the heater is running, it
will not be able to perform its cool down purge cycle, which could cause damage to the internal components.
Dia 6.
30mm
Diesel
tank
Fuel standpipe
1/4" x 3/16" Reducer
3/16" Fuel cock
Solenoid Valve
MX60 Only
Fuel pump.
These olives are
neoprene rubber.
'A'.
Heater.
The fitting on the heater uses a neoprene
rubber olive