EasyManuals Logo

Mikuni MY16 User Manual

Default Icon
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
MY
30
:
The thermostat on the MY
30
has a 3
position switch to allow the heater to blow cold air as well
.
First
disconnect the fuel line at the heater end and put into a suitable receptacle
.
Now disconnect one of the cables going to
the glow plug
.
Push the switch on the left side for heat
;
the red LED will illuminate and the heater motor will start
slowly
,
after approximately
40
seconds the fuel pump will start to pulse
.
The heater will go through a cycle and stop
;
switch the thermostat off and then on again to repeat the cycle until fuel is starting to pulse into the receptacle
.
Now
reconnect the fuel line and glow plug terminal and switch the heater back on
.
It should ignite and after approximately
80
seconds the glow plug will switch off and the right hand light will come on on the thermostat
.
The thermostat on the
MY
30
operates the heater between high and low heat
.
Final checks
(
both models
).
Any heater when it is new requires running in to clear any odours from ducting
,
exhaust lagging etc
.
After the heater
has ignited any smoke from the exhaust should clear within
5
minutes
(
unless the heater has been flooded during
priming
).
Continue running the heater and recheck all the items in the final check list
.
Run the heater for two hours at full heat to clear any odours from the ducting etc
.
WARNING
:
1
.
Ensure that no flammable substances are near the heater exhaust pipe
.
2
.
Ensure that there are no obstructions near the exhaust outlet ie
:
Fender or pontoon
.
Note that
exhaust gases are hot
!
3
.
If the heater overheats whilst operating
,
first turn off the operation switch
,
investigate the cause
and rectify before operating the heater again
.
4
.
Always switch the heater off when filling fuel tanks
.
5
.
If ignition fails do not attempt to start the heater more than
3
times
,
you will flood it with diesel
!
-
Investigate the cause and rectify
.
-
7
-
Specifications
Heat output
Air Flow
Rated voltage
Operating voltage
Current consumption
Fuel
Fuel consumption
Operating temperature
CO
2
value in exhaust gas
Smoke value in exhaust
gas
Safety device
Heater dimensions
Weight
Model
:
(
kw
/h)
m
3
/h
D.C.V
D.C.V
A
L/h
Gallon
/h
o
C
o
F
Vol
%
No
.
mm
kg
MY
16
1.9
50
12
/
24
12
v=
10
.5-
14 24
v=
21
-
28
12
v=3.4
A
24
v=1.7
Diesel fuel
0.
22
0.
06
-
40
-
plus
40
-
40
-
plus 104
10
-
11
.5
Max
:3
See operation manual
364
x
146
x
141
3.6
MY
30
Hi
=3.
5
Lo
=1.
75
Hi
=
136
Lo
=
92
12
/
24
12
v=
11
-
14 24
v
=
22
-
28
12
v=3.8/1.
9 24
v=2.0/1
Diesel fuel
Hi
=0.
42
Lo
=0.
21
Hi
=0.
11
Lo
=0.
058
-
40
-
plus
80
(
control box
:
-
40
-
plus
40
)
-
40
-
plus
176
(
control box
-
40
-
plus
104
)
Hi
=
10
-
11.
Lo
=
7- 8
Max
:2
See operation manual
426
x
182
x
179
5.
65
Specifications.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mikuni MY16 and is the answer not in the manual?

Mikuni MY16 Specifications

General IconGeneral
BrandMikuni
ModelMY16
CategoryHeater
LanguageEnglish

Related product manuals