MY
30
:
The thermostat on the MY
30
has a 3
position switch to allow the heater to blow cold air as well
.
First
disconnect the fuel line at the heater end and put into a suitable receptacle
.
Now disconnect one of the cables going to
the glow plug
.
Push the switch on the left side for heat
;
the red LED will illuminate and the heater motor will start
slowly
,
after approximately
40
seconds the fuel pump will start to pulse
.
The heater will go through a cycle and stop
;
switch the thermostat off and then on again to repeat the cycle until fuel is starting to pulse into the receptacle
.
Now
reconnect the fuel line and glow plug terminal and switch the heater back on
.
It should ignite and after approximately
80
seconds the glow plug will switch off and the right hand light will come on on the thermostat
.
The thermostat on the
MY
30
operates the heater between high and low heat
.
Final checks
(
both models
).
Any heater when it is new requires running in to clear any odours from ducting
,
exhaust lagging etc
.
After the heater
has ignited any smoke from the exhaust should clear within
5
minutes
(
unless the heater has been flooded during
priming
).
Continue running the heater and recheck all the items in the final check list
.
Run the heater for two hours at full heat to clear any odours from the ducting etc
.
WARNING
:
1
.
Ensure that no flammable substances are near the heater exhaust pipe
.
2
.
Ensure that there are no obstructions near the exhaust outlet ie
:
Fender or pontoon
.
Note that
exhaust gases are hot
!
3
.
If the heater overheats whilst operating
,
first turn off the operation switch
,
investigate the cause
and rectify before operating the heater again
.
4
.
Always switch the heater off when filling fuel tanks
.
5
.
If ignition fails do not attempt to start the heater more than
3
times
,
you will flood it with diesel
!
-
Investigate the cause and rectify
.
-
7
-
Specifications
Heat output
Air Flow
Rated voltage
Operating voltage
Current consumption
Fuel
Fuel consumption
Operating temperature
CO
2
value in exhaust gas
Smoke value in exhaust
gas
Safety device
Heater dimensions
Weight
Model
:
(
kw
/h)
m
3
/h
D.C.V
D.C.V
A
L/h
Gallon
/h
o
C
o
F
Vol
%
No
.
mm
kg
MY
16
1.9
50
12
/
24
12
v=
10
.5-
14 24
v=
21
-
28
12
v=3.4
A
24
v=1.7
Diesel fuel
0.
22
0.
06
-
40
-
plus
40
-
40
-
plus 104
10
-
11
.5
Max
:3
See operation manual
364
x
146
x
141
3.6
MY
30
Hi
=3.
5
Lo
=1.
75
Hi
=
136
Lo
=
92
12
/
24
12
v=
11
-
14 24
v
=
22
-
28
12
v=3.8/1.
9 24
v=2.0/1
Diesel fuel
Hi
=0.
42
Lo
=0.
21
Hi
=0.
11
Lo
=0.
058
-
40
-
plus
80
(
control box
:
-
40
-
plus
40
)
-
40
-
plus
176
(
control box
-
40
-
plus
104
)
Hi
=
10
-
11.
Lo
=
7- 8
Max
:2
See operation manual
426
x
182
x
179
5.
65
Specifications.