EasyManua.ls Logo

MIMAKI CJV150-130 - 6.4.3 SL2 H PCB Assy

MIMAKI CJV150-130
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2014 MIMAKI ENGINEERING CO.,LTD. 6.4.3 P.1
1
2
3
4
5
6
7
8
6.4.3 SL2H PCB Assy
Work procedures
1. Remove the following covers.
• Top cover R
• Slider PCB Cover
2. Move the ink carriage onto the station and disconnect all cables
from PCB.
3. Remove the screws (x3) and then remove the SL2H PCB Assy.
4. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15 minutes
before restarting the operation. It is very dangerous if sleep mode functions mistakenly during the
operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pressure
part of PCBs. Take care to avoid contact with it.
SL2H PCB Assy
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > SL2H PCB Assy
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0
Rev.

Table of Contents