11
GB
SPECIFICATIONS
Main unit
Display temperature range : -50.0° C to 70.0°C
(-58.0° F to 158.0°F)
Proposed operating range : - 5.0° C to 50.0°C
( 23.0° F to 122.0°F)
Temperature resolution : 0.1° C ( 0.2°F)
Temperature compensation : -10.0° C to 60.0° C
(14.0° F to 140.0° F)
Relative Humidity : 25% RH to 90% RH
Operating range
Remote thermo-hygro unit
Display temperature range : -50.0° C to 70.0°C
(-58.0° F to 158.0°F)
Proposed operating range
W/Alkaline batteries : -20.0° C to 60.0°C
( -4.0° F to 140.0°F)
W/Lithium batteries : -50.0° C to 60.0°C
(-58.0° F to 140.0°F)
Temperature resolution : 0.1° C ( 0.2°F)
Temperature compensation : -10.0° C to 60.0° C
(14.0° F to 140.0° F)
Relative Humidity : 25% RH to 90% RH
Operating range
General
RF Transmission Frequency : 433 MHz
No. of Remote unit : Maximum of 3
RF Transmission Range : Maximum 100 meters
Temperature compensation : 0.1° C ( 0.2°F)
Temperature sensing cycle : around 40 seconds
Power
Main unit : 2 pcs UM-3 or “AA” 1.5V
battery
Remote sensing unit : 2 pcs UM-3 or “AA” 1.5V
battery
Weight
Main unit : 200 gm
Remote sensing unit : 80.5 gm
Dimensions
Main unit : 130 x 117 x 26 mm
Remote sensing unit : 105 x 70 x 21 mm