i
© 2006 Shenzhen Mindray Bio-medical Electronics Co., Ltd. All rights Reserved.
For this Operation Manual, the issued Date is 2006-03 (Version: 1.2).
Intellectual Property Statement
SHENZHEN MINDRAY BIO-MEDICAL ELECTRONICS CO., LTD. (hereinafter called
Mindray) owns the intellectual property rights to this Mindray product and this
manual. This manual may refer to information protected by copyrights or patents and
does not convey any license under the patent rights of Mindray, nor the rights of
others. Mindray does not assume any liability arising out of any infringements of
patents or other rights of third parties.
Mindray intends to maintain the contents of this manual as confidential information.
Disclosure of the information in this manual in any manner whatsoever without the
written permission of Mindray is strictly forbidden.
Release, amendment, reproduction, distribution, rent, adaption and translation of this
manual in any manner whatsoever without the written permission of Mindray is
strictly forbidden.
, , , , are the registered
trademarks or trademarks owned by Mindray in China and other countries. All
other trademarks that appear in this manual are used only for editorial purposes
without the intention of improperly using them. They are the property of their
respective owners.
Responsibility on the Manufacturer Party
Contents of this manual are subject to changes without prior notice.
All information contained in this manual is believed to be correct. Mindray shall not
be liable for errors contained herein nor for incidental or consequential damages in
connection with the furnishing, performance, or use of this manual.
Mindray is responsible for safety, reliability and performance of this product only in
the condition that:
all installation operations, expansions, changes, modifications and repairs of this
product are conducted by Mindray authorized personnel;
the electrical installation of the relevant room complies with the applicable
national and local requirements;
the product is used in accordance with the instructions for use.
WARNING:
It is important for the hospital or organization that employs this
equipment to carry out a reasonable service/maintenance plan.
Neglect of this may result in machine breakdown or injury of human
health.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray BS-200 and is the answer not in the manual?

Mindray BS-200 Specifications

General IconGeneral
Throughput200 tests/hour
Wavelength Range340-800 nm
Light SourceHalogen lamp
Absorbance Range0-3.0 Abs
Measurement PrinciplePhotometric
Sample Capacity40 positions
Reagent Capacity40 positions
Reagent Positions40 positions
Sample Positions40 positions
Sample Volume2-35 μL
Operating SystemWindows-based
Power RequirementsAC 110-220V, 50/60 Hz
Reagent Volume20 ~ 350 μL
Assay TypesEndpoint, Kinetic, Fixed-time