EasyManua.ls Logo

Minebea Intec MiNexx-link-E PR 5215/10 - Page 36

Default Icon
150 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Device installation | 4.3 - Hardware construction | 36
Technical data
Description Data
External connection 4-pin plug connector
Number of inputs 3 (DI1, DI2, DI3)
Input voltage Low: U
DC
= 0…5V
High: U
DC
= 10…30V
Passive: external power supply required
Input current <11mA @ U
DC
= 24V
<5mA @ U
DC
= 12V
Signals DIGND (-) common for all inputs
Potential isolation yes, via optocoupler
Cable length max. 50 m, screened
Example:
Contact input
Supply unitU
DC
=24V0.5A
If the voltage at terminals (in this example: DI1-DIGND) is U
DC
=10V,
inputDI1 is active(true).

Table of Contents