RIO SERIES ON-SITE GENERATOR
M1-M5 H1-H5
Installation, Operation, and Maintenance
Manual
March 26, 2019

Table of Contents

Questions and Answers

  • W
    welchphyllisAug 19, 2025
    What to do if the MIOX Portable Generator shows high brine pump voltage?
    • J
      Joseph FernandezAug 19, 2025
      If your MIOX Portable Generator shows a high brine pump voltage, several factors could be responsible. First, check to ensure the system has an adequate brine supply. Second, inspect fuse F9 on the control interface board. Third, check fuse F6 on the control interface board. Fourth, the brine solenoid may have failed and needs replacement. Fifth, mineral deposits may have fouled the cell; verify your water softener is working correctly and that the salt meets the requirements. Finally, the cell may be worn out and require replacement.
  • S
    saramyersAug 21, 2025
    Why does my MIOX RIO show a very high oxidant temperature?
    • C
      Catherine McdanielAug 21, 2025
      If the MIOX Portable Generator displays a 'Very High Oxidant Temp' message, it could be due to several reasons. First, ensure the water flow is within the system's specifications. Second, check fuse F10 on the control interface board. Third, inspect fuse F17 on the control interface board.
  • N
    Nicole LoweAug 23, 2025
    How to troubleshoot no air flow in MIOX RIO?
    • B
      Brad SanchezAug 23, 2025
      If you notice no air flow in your MIOX Portable Generator, first verify that the slow switch is physically moving when the fan is turned on. Next, check the vent system for any obstructions. Finally, reset the fan breaker if it has tripped.
  • B
    Brandon FosterAug 26, 2025
    What to do when the MIOX RIO Portable Generator has a rupture disk failure?
    • J
      Joshua CampbellAug 26, 2025
      If your MIOX Portable Generator experiences a rupture disk failure, first verify that the pressure in the cell plumbing is less than 25 PSI by observing the pressure gauge in the plumbing compartment. Second, check the cell outlet plumbing for any blockages or closed valves. Third, inspect fuse F12 on the control interface board.
  • J
    Jordan LambertAug 27, 2025
    Why does the contactor fail to close in my MIOX RIO?
    • M
      Melissa BerryAug 28, 2025
      If the contactor fails to close in your MIOX Portable Generator, it could be due to several reasons. First, check for a red light on the phase detection device (PM1) on the switch gear panel. Second, inspect fuse F3 on the switch gear panel. Third, check fuse F5 on the control interface board.
  • L
    lisa67Aug 29, 2025
    How to fix low water pressure in MIOX Portable Generator?
    • E
      Elizabeth LopezAug 30, 2025
      If your MIOX Portable Generator indicates low water pressure, first ensure that the water pressure meets the system's specifications. Second, verify the operation of the water boost pumps and check fuse F1 on the control interface board.
  • R
    Robert WrightSep 1, 2025
    What causes a low water temperature in my MIOX RIO Portable Generator?
    • R
      rbeasleySep 1, 2025
      If your MIOX Portable Generator is showing a 'Low H2O Temp' error, it could be due to several reasons. First, check the feed water temperature and contact customer service if it's below 40°F. Second, replace the cell inlet thermowell. Third, check fuse F18 on the control interface board.
  • J
    Jim RobertsSep 3, 2025
    What causes a very high cell current in MIOX Portable Generator?
    • A
      Angela ReevesSep 3, 2025
      If the MIOX Portable Generator shows a 'Very High Cell Current' message, first check the fuse for the water solenoid. Second, the water flow control valve might have failed. Third, the brine proportion pump may be malfunctioning.
  • C
    christopher82Sep 5, 2025
    Why is the cell current high in my MIOX RIO?
    • C
      Cristian ColeSep 5, 2025
      If your MIOX Portable Generator displays a 'High Cell Current' message, first verify that the water flow is within the system's specifications. Second, check fuse F10 on the control interface board. Third, the brine proportion pump may be malfunctioning.
  • A
    Angela EvansSep 7, 2025
    How to troubleshoot cell current variation in MIOX RIO Portable Generator?
    • S
      Sandra HubbardSep 8, 2025
      If your MIOX Portable Generator is experiencing cell current variation, first determine which sensor failed using a DC amp meter. Second, the cell may be worn out. Third, verify the leads are tightened to the torque specification.

Summary

RIO Series OSG System and Ancillary Components

Electrolytic Cell

Describes the proprietary membrane-less electrolytic cell and its configuration.

Water Softener

Explains the need for soft water and limits on water hardness for the OSG.

Brine Generator

Details the capacity range and components of the brine generators.

Installation

SAFETY PRECAUTIONS AND WARNINGS

Provides crucial safety precautions and warnings for installation and operation.

Recommended Tools for Installation: RIO Series OSG

System Description

Electric Connections Required for Start-Up

Electrical Power Connection

Explains the routing and connection of the main power cable to the OSG.

Control System;Rear Panel Connections

Plumbing Connections Required for Startup

Feed Water Connection

Details feed water requirements, pressure, and flow control for the OSG.

Brine Feed Connection

Oxidant Discharge

Oxidant Storage Tank Installation

Ventilation Requirements

Outlines the mandatory drop tube and vent requirements for MIOX oxidant tanks.

Ventilation Requirements

Cell Installation and Removal

Removal

Provides detailed steps for safely removing the electrolytic cell from the OSG.

Installation

Provides detailed steps for safely installing the electrolytic cell into the OSG.

Electrical Connections

Cell Lead;Bussbar Connection

Plumbing Connections

Operations

Safety Precautions and Warnings

Lists critical safety precautions and warnings for operating the OSG.

Initial Settings and Startup Checks

Outlines initial settings and startup checks before operating the OSG.

Initial Salt Filling

Checks Prior to Startup

Routine Operations

Startup Sequence;Operating Window

Operation Controls

Modes of Operation

Lists and describes the various operating modes of the OSG.

Fault Conditions

Fault Name and Condition

Lists fault names, conditions, time delays, and system responses.

Fault Recovery

Describes how the system attempts to automatically reset from certain hard faults.

Water Flow Control Valve Reset Procedure

System Shutdown procedure

General Periodic Maintenance

Weekly Maintenance

Monthly Maintenance

Quarterly Maintenance

Annual Maintenance

Electrolytic Cell Replacement

Troubleshooting Guide

Very High Oxidant Temp

Lists causes and remedies for high oxidant temperature faults.

High Brine Pump Voltage

Lists causes and remedies for high brine pump voltage faults.

Low Brine Pump Voltage

Lists causes and remedies for low brine pump voltage faults.

No Air Flow

Rupture Disk Failure

Contactor Failed to Close

Contactor Failed to Open

Very High Cell Current

Low Cell Voltage

High Cell Current

Low Water Pressure

Diode Temperature

Low H2 O Temp

DA System Failure

Cell Current Variation

Procedures

Brine Pump Replacement

Provides detailed instructions for replacing the brine pump.

Rupture Disk Maintenance

Oxidant Demand Testing

Setup Calculations

Procedure

Oxidant Demand Determination

Chlorine Production Testing

Measuring Chlorine Concentration

Measuring Flow

Calculating Total Chlorine Production

MIOX RIO Series Specifications