RIO SERIES ON-SITE GENERATOR
M1-M5 H1-H5
Installation, Operation, and Maintenance
Manual
March 26, 2019

Table of Contents

Questions and Answers

  • K
    Kenneth PerkinsAug 19, 2025
    What to do if the MIOX RIO H5 shows high brine pump voltage?
    • L
      Lisa WilsonAug 19, 2025
      If your MIOX Portable Generator shows a high brine pump voltage, several factors could be responsible. First, check to ensure the system has an adequate brine supply. Second, inspect fuse F9 on the control interface board. Third, check fuse F6 on the control interface board. Fourth, the brine solenoid may have failed and needs replacement. Fifth, mineral deposits may have fouled the cell; verify your water softener is working correctly and that the salt meets the requirements. Finally, the cell may be worn out and require replacement.
  • A
    Ashley ChapmanAug 21, 2025
    Why does my MIOX RIO H5 Portable Generator show a very high oxidant temperature?
    • L
      laurapetersAug 22, 2025
      If the MIOX Portable Generator displays a 'Very High Oxidant Temp' message, it could be due to several reasons. First, ensure the water flow is within the system's specifications. Second, check fuse F10 on the control interface board. Third, inspect fuse F17 on the control interface board.
  • R
    Ricardo MartinAug 25, 2025
    How to troubleshoot no air flow in MIOX RIO H5 Portable Generator?
    • J
      Jesse CochranAug 25, 2025
      If you notice no air flow in your MIOX Portable Generator, first verify that the slow switch is physically moving when the fan is turned on. Next, check the vent system for any obstructions. Finally, reset the fan breaker if it has tripped.
  • A
    Anthony McgeeAug 26, 2025
    What to do when the MIOX RIO H5 Portable Generator has a rupture disk failure?
    • B
      Brianna AguirreAug 26, 2025
      If your MIOX Portable Generator experiences a rupture disk failure, first verify that the pressure in the cell plumbing is less than 25 PSI by observing the pressure gauge in the plumbing compartment. Second, check the cell outlet plumbing for any blockages or closed valves. Third, inspect fuse F12 on the control interface board.
  • J
    Jason WellsAug 28, 2025
    Why does the contactor fail to close in my MIOX RIO H5?
    • D
      Daniel IrwinAug 28, 2025
      If the contactor fails to close in your MIOX Portable Generator, it could be due to several reasons. First, check for a red light on the phase detection device (PM1) on the switch gear panel. Second, inspect fuse F3 on the switch gear panel. Third, check fuse F5 on the control interface board.
  • E
    Erin SullivanAug 30, 2025
    How to fix low water pressure in MIOX RIO H5?
    • M
      Matthew McbrideAug 30, 2025
      If your MIOX Portable Generator indicates low water pressure, first ensure that the water pressure meets the system's specifications. Second, verify the operation of the water boost pumps and check fuse F1 on the control interface board.
  • D
    dannyflowersSep 1, 2025
    What causes a low water temperature in my MIOX RIO H5 Portable Generator?
    • B
      Brian SchultzSep 1, 2025
      If your MIOX Portable Generator is showing a 'Low H2O Temp' error, it could be due to several reasons. First, check the feed water temperature and contact customer service if it's below 40°F. Second, replace the cell inlet thermowell. Third, check fuse F18 on the control interface board.
  • H
    heidi53Sep 3, 2025
    What causes a very high cell current in MIOX Portable Generator?
    • B
      Brandon WrightSep 3, 2025
      If the MIOX Portable Generator shows a 'Very High Cell Current' message, first check the fuse for the water solenoid. Second, the water flow control valve might have failed. Third, the brine proportion pump may be malfunctioning.
  • R
    Ricardo MccormickSep 5, 2025
    Why is the cell current high in my MIOX RIO H5?
    • M
      Mary SullivanSep 5, 2025
      If your MIOX Portable Generator displays a 'High Cell Current' message, first verify that the water flow is within the system's specifications. Second, check fuse F10 on the control interface board. Third, the brine proportion pump may be malfunctioning.
  • A
    Andrea FarleySep 8, 2025
    How to troubleshoot cell current variation in MIOX RIO H5?
    • C
      Chelsea Cruz MDSep 8, 2025
      If your MIOX Portable Generator is experiencing cell current variation, first determine which sensor failed using a DC amp meter. Second, the cell may be worn out. Third, verify the leads are tightened to the torque specification.

Summary

RIO Series OSG System and Ancillary Components

Electrolytic Cell

Describes the proprietary membrane-less cell producing oxidants and its pressure reaction.

Installation

SAFETY PRECAUTIONS AND WARNINGS

Crucial safety measures for installation, including codes, venting, and grounding.

Recommended Tools for Installation: RIO Series OSG

System Description

Electric Connections Required for Start-Up

Electrical Power Connection

Describes routing the power cable and connecting it to the switch gear compartment.

Control System;Rear Panel Connections

Plumbing Connections Required for Startup

Feed Water Connection

Details feed water requirements, pressure, and flow control for the OSG.

Brine Feed Connection

Oxidant Discharge

Brine Pressure Boost System Installation (Optional)

Oxidant Storage Tank Installation

Feed Line Connection;Injection System

Cell Installation and Removal

Removal

Step-by-step procedure for removing the OSG cell safely.

Installation

Step-by-step procedure for installing the OSG cell correctly.

Electrical Connections

Cell Lead;Bussbar Connection

Details how to connect cell leads to buss bars using electric joint compound.

Plumbing Connections

Operations

Safety Precautions and Warnings

Essential safety warnings for operating the OSG, including solution use and venting.

Initial Settings and Startup Checks

Steps for initial electrical check and filling the brine generator with salt.

Checks Prior to Startup

Brine Boost Operation

Water Softener Operation

Routine Operations

Startup Sequence;Operating Window

Operation Controls

Fault Conditions

Water Flow Control Valve Reset Procedure

System Shutdown procedure

General Periodic Maintenance

Daily Maintenance

Daily checks including salt level and initial operation monitoring.

Weekly Maintenance

Monthly Maintenance

Quarterly Maintenance

Annual Maintenance

Electrolytic Cell Replacement

Troubleshooting Guide

Procedures

Brine Pump Replacement

Detailed steps for removing and installing a new brine pump.

Removing The Old Brine Pump

Step-by-step instructions for safely removing the existing brine pump.

Installing the New Brine Pump

Rupture Disk Maintenance

Replacing the Rupture Disk Diaphragm

Procedures for safely replacing a ruptured rupture disk diaphragm.

Rupture Probe Maintenance

Acid Washing the Cell

Oxidant Demand Testing

Setup Calculations

Procedure

Oxidant Demand Determination

Chlorine Production Testing

Preparing Chlorine Demand-Free Water

Methods for preparing demand-free water essential for accurate testing.

Measuring Chlorine Concentration

Measuring Flow

Calculating Total Chlorine Production

Formulas to calculate daily chlorine production based on concentration and flow.