Original Instructions Version June 16
Storage
Remove the spark plug; pour a small amount of oil into the cylinder. Rotate the
crankshaft several times using the starting rope in order to distribute the oil. Put the
spark plug back in.
Remove the fuel from the machine.
Gear Case
Remove the bolt (a) on the gear case, top up the gearbox using Lithium grease and refit
the bolt, every 15 hours use.