EasyManua.ls Logo

Mitsubishi Electric FR-A500 User Manual

Mitsubishi Electric FR-A500
257 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TRANSISTORIZED INVERTER
INSTRUCTION MANUAL
FR-A500
OUTLINE
Chapter 1
INSTALLATION
AND WIRING
Chapter 2
OPERATION
/CONTROL
Chapter 3
PARAMETERS
Chapter 4
PROTECTIVE
FUNCTIONS
Chapter 5
SPECIFICATIONS
Chapter 7
OPTIONS
Chapter 8
PRECAUTIONS FOR
MAINTENANCE AND
INSPECTION
Chapter 6
FR-A520-0.4K to 55K-NA
FR-A540-0.4K to 55K-NA,-EC
HIGH FUNCTION
&
LOW ACOUSTIC NOISE
FR-A500-NA,-EC
TRANSISTORIZED INVERTER
INSTRUCTION MANUAL
HEAD OFFICE:MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100-8310
IB(NA)-66790-J (0502) MDOC Printed in japan Specifications subject to change without notice.

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-A500 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-A500
CategoryInverter
LanguageEnglish

Summary

CHAPTER 1 OUTLINE

Pre-Operation Information

Provides preliminary information before operating the inverter.

Basic Configuration

Details the essential devices required for inverter operation and proper system configuration.

Structure

Describes the physical appearance and structure of the inverter, including front and rear views.

CHAPTER 2 INSTALLATION AND WIRING

Installation

Provides instructions for installing the inverter safely and correctly, considering environmental factors.

Wiring

Details the terminal connection diagrams and wiring instructions for the main and control circuits.

Other Wiring

Discusses power supply harmonics, inverter-generated noises, leakage currents, and specific wiring.

CHAPTER 3 OPERATION/CONTROL

Pre-Operation Information

Details devices and parts required for different operation modes (external, PU, combined).

Operation Panel

Explains the names and functions of the operation panel (FR-DU04) components and keys.

Operation

Covers pre-operation checks and outlines different operation modes like external and PU operation.

CHAPTER 4 PARAMETERS

Parameter Lists

Lists all available parameters, including their numbers, names, setting ranges, and references.

Parameter Function Details

Explains the function, setting range, and related parameters for each setting.

CHAPTER 5 PROTECTIVE FUNCTIONS

Errors (Alarms)

Lists and defines various error codes (alarms) that indicate faults or protective function activation.

Troubleshooting

Provides guidance on identifying and resolving common issues encountered during inverter operation.

CHAPTER 6 PRECAUTIONS FOR MAINTENANCE AND INSPECTION

Precautions for Maintenance and Inspection

Details general precautions for maintenance and inspection, including safety checks after power off.

Check Items

Lists daily inspection items for motor, environment, cooling, vibration, noise, and overheating.

Periodic Inspection

Highlights areas requiring periodic inspection, such as cooling systems, terminals, and conductors.

Insulation Resistance Test Using Megger

Details procedures for performing insulation resistance tests on the main circuit, excluding the control circuit.

Pressure Test

States that pressure tests should not be conducted as they may damage semiconductors.

Daily and Periodic Inspection

Provides a detailed table for daily and periodic inspections, including checks for environment, overall unit, power supply, and circuits.

Replacement of Parts

Lists parts like cooling fans and capacitors that require periodic replacement due to age or wear.

CHAPTER 7 SPECIFICATIONS

Standard Specifications

Provides detailed specifications for the inverter models, including electrical ratings, dimensions, and environmental conditions.

Model Specifications

Lists specifications for NA version models (FR-A520/A540) from 0.4K to 55K, covering capacity, voltage, current, and dimensions.

Common Specifications

Details common specifications for control system, frequency setting, input signals, and output signals.

Outline Dimension Drawings

Provides dimensional drawings for the inverter and operation panel for installation planning.

CHAPTER 8 OPTIONS

Option List

Lists available stand-alone and plug-in options with their applications and specifications.

Stand-alone Options

Lists stand-alone options like parameter units, heatsinks, filters, reactors, and brake units.

Plug-in Dedicated Options

Lists plug-in options for digital input, digital output, analog output, communication, and special functions.

Options with FR-A5AP

Explains addition of Pr. 285 for excessive speed deviation and Pr. 376 for wire break detection.

Options with Communication

Details settings for switching between PU and network operation modes and using external terminals for mode switching.

APPENDICES

Instruction Code List

Lists instruction codes for reading and writing parameters, and link parameter extension settings.

Operating the Inverter with Single-Phase Power Supply

Provides ratings and cautions for operating the inverter using a single-phase power supply.

Related product manuals