EasyManua.ls Logo

Mitsubishi Electric FR-A840-00930 (37K) User Manual

Mitsubishi Electric FR-A840-00930 (37K)
856 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INVERTER
INVERTER FR-A800 INSTRUCTION MANUAL (DETAILED)
J
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
IB(NA)-0600503ENG-J(1705)MEE Printed in Japan Specifications subject to change without notice.
FR-A800
INSTRUCTION MANUAL (DETAILED)
FR-A820-00046(0.4K) to 04750(90K)(-GF)
FR-A840-00023(0.4K) to 06830(280K)(-GF)
FR-A842-07700(315K) to 12120(500K)(-GF)
FR-A846-00023(0.4K) to 03610(132K)
High functionality and high performance
MODEL
FR-A800
INSTRUCTION MANUAL
MODEL
CODE
XXX-XXX
Model
FR-A800
Instruction Manual (Detailed)
Model code 1A2-P52

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-A840-00930 (37K) Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-A840-00930 (37K)
CategoryInverter
LanguageEnglish

Summary

MITSUBISHI ELECTRIC INVERTER FR-A800 INSTRUCTION MANUAL (DETAILED)

Chapter 1 INTRODUCTION

1.1 Product checking and accessories

Unpack the product and check the rating plate and the capacity plate of the inverter to ensure that the model agrees with the order and the product is intact.

Chapter 2 INSTALLATION AND WIRING

2.1 Peripheral devices

Check the model of the inverter you purchased. Appropriate peripheral devices must be selected according to the capacity.

2.3 Installation of the inverter and enclosure design

Determines the structure, size, and device layout of the enclosure by fully considering the conditions such as heat generation and operating environment.

CHAPTER 3 PRECAUTIONS FOR USE OF THE INVERTER

3.1 Electro-magnetic interference (EMI) and leakage currents

Explains precautions for EMI and leakage currents.

3.6 Checklist before starting operation

Provides a checklist before starting operation.

CHAPTER 4 BASIC OPERATION

4.1 Operation panel (FR-DU08)

Explains the operation panel (FR-DU08).

4.5 Basic operation procedure (PU operation)

Explains the basic operation procedure when using the PU operation mode.

CHAPTER 5 PARAMETERS

5.1 Parameter list

Lists all parameters with their initial values, setting ranges, and descriptions.

5.2 Control method

Explains the different control methods available with this inverter.

5.3 Speed control under Real sensorless vector control, vector control, PM sensorless vector control

Explains speed control under Real sensorless vector control, Vector control, and PM sensorless vector control.

5.4 Torque control under Real sensorless vector control and Vector control

Explains torque control under Real sensorless vector control and Vector control.

5.5 Position control under vector control and PM sensorless vector control

Explains position control under vector control and PM sensorless vector control.

(D) Operation command and frequency command

Explains operation command and frequency command.

(H) Protective function parameter

Explains protective function parameters.

CHAPTER 6 PROTECTIVE FUNCTIONS

6.1 Inverter fault and alarm indications

Explains inverter faults and alarm indications.

6.2 Reset method for the protective functions

Explains the reset method for the protective functions.

6.5 Causes and corrective actions

Explains the causes and corrective actions for various faults and warnings.

CHAPTER 7 PRECAUTIONS FOR MAINTENANCE AND INSPECTION

7.1 Inspection item

Details the inspection items for maintenance and inspection.

CHAPTER 8 SPECIFICATIONS

8.1 Inverter rating

Provides the inverter rating specifications.

Related product manuals